Vantage Pro2

S e n s o r   C h a r t s

P a c k a g e   D i m e n s i o n s

 

Product #

Package Dimensions

(Length x Width x Height)

Package Weight

UPC Codes

6152C

17.0" x 11.0" x 13.0" 

(410 mm X 264 mm x 330 mm) 

12.8 lbs. (5.8 kg)

011698 00755 4

6152CEU

011698 00772 1

6152CUK

011698 00773 8

6162C

13.3 lbs. (6.0 kg)

011698 00756 1

6162CEU

011698 00774 5

6162CUK

011698 00775 2

Figure 1. Temperature Accuracy

Temperature Accuracy

0.0

1.0

2.0

3.0

4.0

5.0

-40

-20

0

20

40

60

80

100

120

140

Temperature (°F)

Temperature Accuracy

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

-40

-30

-20

-10

0

10

20

30

40

50

60

Temperature (°C)

Accuracy (°F)

Accuracy (°C)

Rain Rate Resolution

Low Range 

Resolution (in.)

10.0

1.00

0.10

0.01

0     1     2     3     4     5     6    7     8     9    10   11   12   13   14   15   16   17   18   19   20 

Rain Rate (in/hr.)

Rain Rate Resolution

Full Range 

Resolution (in.)

100.00

10.00

1.00

0.10

0.01

0     1     2     3     4     5     6    7     8     9    10   11   12   13   14   15   16   17   18   19   20 

Rain Rate (in/hr.)

Figure 2. Low Range Rain Rate Resolution

Figure 3. Full Range Rain Rate Resolution

Summary of Contents for 6152C

Page 1: ...re sensor readings Integrated Sensor Suite ISS Operating Temperature 40 to 150 F 40 to 65 C Non operating Temperature 40 to 158 F 40 to 70 C Current Draw 5 mA average at 4 to 6 VDC for ISS only 10 mA average for both console and ISS Connectors Sensor Modular RJ 11 Cable Type 4 conductor 26 AWG Cable Length Anemometer 40 12 m included 240 73 m maximum recommended Note Maximum displayable wind decre...

Page 2: ...isplay data describes the current reading for each weather variable In most cases the variable lists the most recently updated reading or calculation Some current variable displays can be adjusted so there is an offset for the reading Current Graph Data Current data appears in the right most column in the console graph and represents the latest value within the last period on the graph totals can ...

Page 3: ...le Accuracy 8 seconds month Adjustments Time Automatic Daylight Savings Time for users in North America and Europe that observe it in AUTO mode MANUAL setting available for all other areas Date Automatic Leap Year Alarms Once per day at set time when active Dewpoint calculated Resolution and Units 1 F or 1 C user selectable C is converted from F rounded to nearest 1 C Range 105 to 130 F 76 to 54 C...

Page 4: ...h Historical Graph Data Hourly Calculations Daily Monthly Highs Alarm High Threshold from Instant Calculation Humidity Inside Relative Humidity sensor located in console Resolution and Units 1 Range 1 to 100 RH Accuracy 3 0 to 90 RH 4 90 to 100 RH Update Interval 1 minute Current Display Data Instant user adjustable offset available Current Graph Data Instant Hourly Reading Daily Monthly High and ...

Page 5: ...ge for Rain Alarms 0 to 99 99 0 to 999 7 mm Rain Rate Resolution and Units 0 01 or 0 1mm user selectable at typical rates see Fig 2 and 3 Range 0 0 04 hr 1 mm hr to 96 hr 0 to 2438 mm hr Accuracy 5 for rates less than 5 per hour 127 mm hr Update Interval 20 to 24 seconds Calculation Method Measures time between successive tips of rain collector Elapsed time greater than 15 minutes or only one tip ...

Page 6: ...able Current Graph Data Instant Daily Monthly Yearly High and Low Historical Graph Data Hourly Readings Daily Monthly Yearly Highs and Lows Alarms High and Low Thresholds from Instant Reading Temperature Humidity Sun Wind Index requires solar radiation sensor Resolution and Units 1 F or 1 C user selectable C is converted from F rounded to nearest 1 C Range 90 to 165 F 68 to 74 C Accuracy 4 F 2 C t...

Page 7: ...cal Graph Data Hourly Daily and Monthly Lows Alarm Low Threshold from Instant Calculation Wind Direction Range 0 360 Display Resolution 16 points 22 5 on compass rose 1 in numeric display Accuracy 3 Update Interval 2 5 to 3 seconds Current Graph Data Instant Reading user adjustable 10 min Dominant Hourly Daily Monthly Dominant Historical Graph Data Past 6 10 min Dominants on compass rose only Hour...

Page 8: ... 011698 00774 5 6162CUK 011698 00775 2 Figure 1 Temperature Accuracy Temperature Accuracy 0 0 1 0 2 0 3 0 4 0 5 0 40 20 0 20 40 60 80 100 120 140 Temperature F Temperature Accuracy 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 4 5 5 0 40 30 20 10 0 10 20 30 40 50 60 Temperature C Accuracy F Accuracy C Rain Rate Resolution Low Range Resolution in 10 0 1 00 0 10 0 01 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1...

Reviews: