background image

8

Software Installation and Setup

About the Walkthrough

Weatherlink includes a Walkthrough option that steps you through the station 
configuration procedure. After adding a new station, the software 
automatically asks if you want to use Walkthrough to set up your station. You 
can, of course, choose “No” and set up the station by choosing all of the 
necessary commands from the menus. A Walkthrough command is included in 
the 

Setup

 menu that lets you begin this set of procedures at any time.

Note: Where necessary, the software will automatically dial a phone modem station. 

If you select 

Yes

 to begin the walkthrough, the software takes you through the 

following dialog boxes:

Station Configuration

 — Set station name, model, accessories, download 

options, and data file extension.

Choose Units

 — Select units of measure in which station information is 

displayed.

• Serial Port Settings — 

Set COM port to which data logger is connected. 

The COM port is created by the software included with your USB/serial 
port adapter. Specify modem connection settings such as baud rate, phone 
number, and modem initialization string.

Set Rain Calibration 

— Set the station’s rainfall calibration number.

Enter Year-to-Date Rainfall 

— Set the rainfall amount on the station and 

on the software. You must enter this information from the software if you 
want you station and software readings to agree.

• Set  Time  and  Date  —

Set the time and date on the station, software, and 

computer and make sure all three are synchronized.

Note: When you set the time and date, you will be prompted to clear your archive memory. If 

you do not clear archive memory, you may end up with data stored at an incorrect time or 
duplicate records. We recommend that you download before setting the time (unless you 
are creating a brand new station) so you may safely clear the archive memory.

Set Archive Interval

 — Set the interval at which data will be stored in the 

data logger’s memory. This will clear any data stored in the data logger.

Set Station Alarms

 — Set alarm thresholds on the station.

• Set Auto Download Time(s) — Specify the stations and the times at which 

you want data automatically downloaded to your computer each day.
At each step in the walkthrough procedure, the software will provide con-
firmation boxes prompting you to indicate whether or not you wish to con-
tinue. To continue, click 

OK

. To skip any step and move to the next, click

 

Skip

. To cancel the entire walkthrough procedure, click 

Cancel

.

Summary of Contents for WeatherLink

Page 1: ......

Page 2: ...esidential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio c...

Page 3: ...des 8 2 4 m cable to link your station to your com puter 9 pin DIN connector WeatherLink software CD ROM Required Accessories You will need to install a third party serial port adapter on your Macinto...

Page 4: ...interval Database files containing data stored at a 30 minute archive inter val require approximately 36K of disk space per month of data The file size changes in a linear fashion depending on the ar...

Page 5: ...ing power will cause these stored weather values to be erased Use WeatherLink to re enter these values as well as the time and date after restoring power to the console 2 Remove the mounting base from...

Page 6: ...or to the serial port adapter 12 Connect the long data logger cable to the DIN connector The cable connecting the data logger to the computer is 8 2 4 m long If you need to place the station console m...

Page 7: ...1200 baud change the setting before connecting the data logger to the console 6 Connect the short data logger cable to the cable jack marked Weather Link on the bottom of your weather station console...

Page 8: ...Phone Modem Connections If you indicate a phone modem connection when setting up your station the software automatically dials the station whenever you initiate a program action that requires the soft...

Page 9: ...s data base which means naming the station configuring the software to work with that station and with your computer hardware and setting station values such as time barometric pressure total rainfall...

Page 10: ...ion Set the station s rainfall calibration number Enter Year to Date Rainfall Set the rainfall amount on the station and on the software You must enter this information from the software if you want y...

Page 11: ...eep will be for the data logger if installed and the third beep is for the display If you do not hear one or more of these beeps contact Technical Support see Contacting Davis Technical Support on pag...

Page 12: ...of the window select the port you want to test If you are using a Keyspan USB Twin Serial adapter or a similar USB to serial port adapter between your weather station and your Macintosh the port show...

Page 13: ...23 Using the record editor to change the record in one day does not change the record in the other day Note Do not delete the duplicate midnight records it may affect your rain database or NOAA month...

Page 14: ...d the correct station before downloading Your data logger may be not be operating properly If this is the case you can restore proper operation by repowering the data logger 1 Remove power from the da...

Page 15: ...echnical Support Most questions can be answered on the phone Note Sorry we are unable to accept collect calls Phone Support 510 732 7814 Monday Friday 7 00 a m 5 30 p m Pacific Time 510 670 0589 Techn...

Page 16: ...harts Ctrl T Set Time Ctrl U Select Units Ctrl V View Download Log Ctrl W Browse Database Ctrl X Auto Fax Settings Ctrl Y View Summary Ctrl Z Close Window F1 Context Sensitive Help F2 Sunrise Sunset R...

Reviews: