TEMPERATURE
Vantage Pro Manual
Page 31
Outside temperature
sensor reading seems
too high
Check calibration number and adjust if
necessary.
Inside temperature
sensor reading seems
too high
Move the Vantage Pro console (or other
temp sensor if you have installed addi-
tional wireless temperature sensors) out of
direct sunlight.
Make sure that the console or sensor is not
in contact with an exterior wall that heats
up in sunlight or when outside tempera-
ture rises.
Make sure the console or sensor is not near
a heater or other internal heat source
(lamps, appliances, etc.).
Check calibration number and adjust if
necessary.
Outside temperature
seems too low
Check calibration number and adjust if
necessary.
Inside temperature
sensor reading seems
too low
Make sure the the console or other tem-
perature sensor is not in contact with an
exterior wall that cools down when out-
side temperature drops.
Make sure the console or other tempera-
ture sensor is not near an air conditoning
vent.
Check calibration number and adjust if
necessary.
Inside humidity seems
too high or too low
Make sure the Vantage Pro console is not
near a humidifier or de-humidifier.
Check calibration number and adjust if
necessary.
Problem
Solution
PG.