Davis & Shirtliff DAYLIFF DX Series Installation & Operating Manual Download Page 10

8

WARNING

3.  OPERATION

This shuts off all flow to the filter. In pool applications it is 
most frequently used to isolate the filter when removing 
the line strainer lid to clean the basket.

CLOSED

WASTE

FILTER

PUMP

FROM POOL

TO POOL

3.2  Maintenance of Filters

DAYLIFF  filters  need  no  routine  maintenance  other  than  regular 
backwashing.  However,  over  time  the  media  will  progressively  clog  and 
become less effective. The period will depend upon the pool installation and 
usage, though is normally some years. Ineffective media becomes apparent 
through reduced filter efficiency and when this occurs re-charging with new 
media will be necessary.

Important Note:-

The pipe connections must be correctly done as shown above. Hand tightening is 
adequate for the MPV unions and under no circumstances should a pipe wrench 
be used. If the union weeps, add more thread tape on the union threads and 
make sure to check that the union O-Ring is in place.

PROBLEM

FILTER

POSSIBLE CAUSE

SOLUTION

Flow rate very high

Water coming 
out not clear

4.  TROUBLE SHOOTING

Regulate flow rate to optimal levels 
to ensure adequate filtration time

Filter not working well 

Check  that  the  filter  is  in  good 
condition

Clogged sand filter

Back wash the filter

Feed pump not working well

Low clean water 
flow

Check  that  the  pump  performance 
has not dropped drastically

Filter clogged

Back wash the filter

System’s pipeline clogged

Check  that  the  pipeline  is  not 
clogged and clean pipe if it's the case

Feed pump failed

Repair or replace the pump

No water supply 
at all

Check  the  right  valves  have  been 
closed  or  opened  for  the  right 
process operation

Filter clogged

Backwash the filter

Valve arrangement control

Feed pump failed

Repair or replace the pump

Summary of Contents for DAYLIFF DX Series

Page 1: ...DX Filter Installation Operating Manual...

Page 2: ...INDEX Davis Shirtliff Ltd 2022 Contents herein are not warranted SPECIFICATIONS 1 1 2 INSTALLATION 3 3 OPERATION 6 4 TROUBLE SHOOTING 8 5 TERMS OF WARRANTY 9...

Page 3: ...connected six position multiport valves with union connections The flange arrangement greatly simplifies installation and media replacement as well as providing a secure watertight seal l Specially d...

Page 4: ...PL550 4 0 07 DPL550 SPP75M DPL750 SPP150M DPX1100 SPP200M DPX1100 SPP300M DPX1500 0 55 0 75 1 5 0 5 2 2 1 5 0 33 0 33 40 000 0 55 Light Use Normal Use Heavy Use Suction Delivery Recommended Piping Siz...

Page 5: ...sequent operational problems The backwash pipe must fall evenly to a suitable discharge point below the level of the filter It is recommended that isolating valves be installed on the pool suction adj...

Page 6: ...FILTER position should line up with the manufacturer s name plate The filter should therefore be positioned to take account of this BEFORE it is charged with media 2 3 Media Charging The filter is pro...

Page 7: ...bottom collector pipes This pipe should now be blocked with paper or a cloth to prevent the ingress of media during charging Charge with media as per the instructions given above Replace the Multiport...

Page 8: ...wo from when the pump is switched on to when flow is observed Stop pump and turn MPV to RINSE Start pump and allow media bed to rinse until waste water is observed as clean Stop pump and turn MPV to F...

Page 9: ...d of returning it to the pool Rinsing should not take more than one minute and again the sight glass on the side of the valve can be used to see when the water is clear WASTE FILTER PUMP TO POOL FROM...

Page 10: ...and under no circumstances should a pipe wrench be used If the union weeps add more thread tape on the union threads and make sure to check that the union O Ring is in place PROBLEM FILTER POSSIBLE C...

Page 11: ...s defects caused by fair wear and tear the effects of careless handling lack of maintenance faulty installation incompetence on the part of the equipment user Acts of God or any other cause beyond the...

Page 12: ...INS503A 12 22...