AIR TURQUOISE SA | Rte du Pré-au-Comte 8 | CH-1844 Villeneuve | +41 (0)21 965 65 65
Test laboratory for paragliders, paraglider harnesses and paraglider reserve parachutes
Line and Riser Measurements of flight test Paraglider
(1)
Report No. :
Sample name:
Date measure:
Place:
Manufacturer:
S/N:
Responsible:
Linked:
Total line length including risers [mm]
Main brake line with diff color than A,B,C main line? Yes
+strap
Manu
(2)
Sample
Diff
Manu
Sample
Diff
Manu
Sample
Diff
Manu
Sample
Diff
Manu
Sample
Diff
Manu
Sample
Diff
Manu
Sample
Diff
Sample
Center
1
6786
6792
6
6700
6706
6
6660
6659
-1
6795
6794
-1
0
0
7128
7127
-1
2
6727
6732
5
6629
6637
8
6662
6662
0
6792
6793
1
0
0
6879
6884
5
3
6786
6791
5
6691
6695
4
6644
6644
0
6769
6765
-4
0
0
6740
6741
1
4
6742
6749
7
6640
6649
9
6645
6648
3
6765
6764
-1
0
0
6688
6692
4
5
6765
6765
0
6651
6660
9
6612
6612
0
6685
6683
-2
0
0
6571
6576
5
6
6730
6732
2
6620
6620
0
6592
6592
-1
6660
6659
-1
0
0
6411
6419
8
7
6709
6713
4
6604
6605
1
6581
6580
-1
6653
6650
-3
0
6417
6425
8
8
6697
6699
2
6596
6594
-2
6586
6588
2
6644
6644
0
0
6607
6614
7
9
6699
6702
3
6603
6606
3
6547
6546
-1
0
0
6419
6428
9
10
6637
6639
2
6544
6548
4
6505
6507
2
0
0
6441
6449
8
11
6577
6580
3
6497
6502
5
6439
6439
0
0
0
Stab line to riser:
6485
6491
6
12
6472
6474
2
6417
6420
3
6394
6395
1
0
0
B
0
13
6416
6417
1
6369
6371
2
6255
6254
-1
0
0
Wing
14
6223
6218
-5
6200
6197
-3
6238
6239
1
0
0
tip
15
0
6185
6185
-1
0
0
Number Cell:
36
0
16
0
0
0
0
Weight of the glider [kg]:
4.44
0
17
0
0
0
0
0
18
0
0
0
0
Tolerance [mm]
(4)
:
±15
0
Riser measurement - total length (inner edge) [mm]
(3)
Acc system configuration max travel
Test Atmosphere AGL
Risers
Std
Acc
Trim
Risers
Std
Acc
No. of risers
3
Pressure [hPa]
981.5
A
526
396
n/a
A
496
366
Tolerance [mm]
5
Humidity [%]
48
A'
526
396
n/a
A'
496
366
Temperature [°C]
21.6
B
526
439
n/a
B
496
409
Carabiner [mm]
30
C
526
526
n/a
C
496
496
Tolerance [mm]
2
n/a
Plausibility check :
Acc
130
*[mm]
Acc
130
*[mm]
*Travel range (distance
[mm]
500
499.7
Trimmer
n/a
[mm]
Trimmer
n/a
[mm]
between A and rear riser)
Another trim configuration
No
[mm]
10000
10001
If yes (description):
Remark:
Instrument validity
date
Laser distance meter
07.09.2023
Uncertainty of instrument [mm]
3
Line measurements system
07.09.2023
Villeneuve
ISO 91.20
A
B
C
D
E
Stab
Brake
PG_1759.2020
Davinci Products
Rhythm2 S
ARTT-S22910-BYRBK
26.03.2021
Claude Thurnheer
(3)
Risers, Std=Trim speed, Acc=Accelerated, AND if trimmer: Open=trimmer open, Closed=trimmer closed, Trim=measured at this position.
(4)
Tolerance line and riser is +/-15 [mm]
Total
length
(incl.
Carabiner
or
connect)
Total
length
(no cara-
biner or
con-
nect)
Present inspection’s scope only extends to the conformity of a given sample, on a given date and in a given place – as mentioned here above. The validation of this report is given by the signature of the test manager on inspection certificate 91.20
(1)
Total length measured from the underside of the glider to the inner edge of the risers with a tenstion of 50 [N]. Measured values do not include the uncertainty/The uncertainty stated is the expanded uncertainty obtained by multiplying the standard uncertainty
by the coverage factor k = 2. The measured values lies within the assigned range of values with a probability of 95%.
(2)
Manu=Values from manufacturer, Sample=Measured by inspector.
RE | rev 18 | 09.09.2020
Page 1 | 1
ISO | 91.24