6
Features and Specifications
© Travis Industries
4150126
100-01418
Installation Options
Residential or Commercial Installations
Raised or Floor Placement
Internal
or
External Chase
Horizontal or Vertical Vent
Bedroom
Approved
BTU Specifications
Natural Gas
Propane
6’ Burner – BTU Input Per Hour
87,000
87,000
7’ Burner – BTU Input Per Hour
101,500
101,500
8’ Burner – BTU Input Per Hour
116,000
116,000
9’ Burner – BTU Input Per Hour
130,500
130,500
10’ Burner – BTU Input Per Hour
145,000
145,000
Fireplace Modules
Category 2 DaVinci Custom Fireplaces™ are shipped in two pieces (called “modules”). There is a master
module and a secondary module. If using an odd length fireplace (e.g. 7’ or 9’ burner), the master
module will be the longer module. For example, a 7’ burner fireplace will have use a master module that
is 4’ long and a secondary module that is 3’ long.
Master Module vs. Secondary Module
When ordering a Category 2 DaVinci Custom Fireplace™ you will need to specify whether the master
module is on the left or right. .
When ordering the fireplace it is critical you specify which side the
master module is located and communicate this with all involved with the installation – the
orientation of the master module affects several installation parameters.
The secondary module
connects to the master module with a flexible gas line, electrical jumper, and LED connections.
Gas, Electrical, and Power Exhaust Hookup
The master module has the gas inlet, electrical connections, and power exhaust collar.
Air Intakes
Both the master and secondary module will have air intake(s). If the fireplace uses a 9’ or 10’ burner, the
fireplace will use 3 intakes. Fireplaces 8’ or shorter use 2 intakes. The air intake duct location varies
depending upon fireplace length (see “Air Intake Duct Location” on page 54).
Power Exhaust
If the fireplace uses a burner that is 7’ or longer, you will need to use the high-volume blower. For shorter
fireplaces, use the low-volume blower. The power exhaust location is always centered on the master
module (the exhaust is not centered on the fireplace, it is centered on the module – see the “Dimensions”
on the following pages for details).
Decimal Conversions
0.125” 1/8”
0.25” 1/4"
0.375” 3/8”
0.5” 1/2"
0.625” 5/8”
0.75” 3/4"
0.875” 7/8”