OPTION 3: CONTINUOUS RUNNING  
(Recommended for race vehicles, very hot climate & cars running on LPG.)

 

 
 

Continuous EWP

®

 operation may be required for some road or race engine 

applications, in some very hot climatic conditions and engines fitted with liquid 

petroleum/butane gas (LPG) conversion. 

 

This option will provide maximum flow from your EWP

®

 under all operating conditions 

without a Digital Controller or a Thermatic Switch fitted. Should you choose this 

method you should retain the engine thermostat and drill one or two holes (suggest 

5mm) in the plate to allow some coolant flow when the thermostat is closed.  

 

 

 

  

 

 

Figure 3:  Wiring Diagram: EWP

®

 Continuous Running 

BATTERY 

+

 

_

 

+VE IGNITION 
SOURCE 

FUSE 

EARTH 

PUMP MOTOR 

RELAY & LOOM 
FROM PUMP 
PACKAGING 

BLACK 

BLUE 

RED 

GREEN 

Summary of Contents for EWP80

Page 1: ...t driven mechanical water pump In addition with a Davies Craig Digital Controller your thermostat can be replaced The major benefits of an Electric Water Pump EWP are removal of the parasitic power losses running a mechanical water pump at any speed reduction of engine warm up time and elimination of heat soak by running the EWP after a hot engine shut down by operating the EWP with the EWP Fan Di...

Page 2: ...n Pump Short 1 N A Scotch Lock 1 N A Ring Terminal 1 N A Self Tapping Screw 1 8515 Wiring Harness 1 N A Relay 1 18510 EWP Rubber Sleeve 3mm 2 18512 Hose Clamps 2 8526 EWP Hardware Bag 1 EWP80 Nylon 12V EWP Components Hardware Bag Components Part Description Qty Part Description Qty 8105 EWP Pump Short 1 N A Scotch Lock 1 8515 Wiring Harness 1 N A Ring Terminal 1 8309 Elbow Adaptor 35mm Nylon 1 N A...

Page 3: ...uctions above for correct EWP fitment ensuring the pump outlet is connected to the hose going into the top of the radiator The pump can be installed in any orientation but to assist air bleeding try to mount the outlet pointing upwards See Section 8 for bleeding instructions Ensure your cooling system is kept full of coolant 2 If you have either an EWP130 or EWP80 assemble the provided EWP Straigh...

Page 4: ... Thermatic Switches Part 0401 or Part 0444 Combine the EWP with either of the approved Davies Craig thermal switches listed here when the EWP is used as a booster pump to assist the existing mechanical water pump cool an overheating engine Connect the thermal switch directly to the battery and your EWP will run on to eliminate heat soak You may leave the thermostat in place but ensure the EWP oper...

Page 5: ... may be exposed to direct sunlight 3 An additional screw is provided for mounting Digital Controller fuse holder where necessary 4 Mount Remote Test Light in a location which will be visible The Test Light may be fitted by inserting it through a 4 6mm hole drilled in a plastic area of the interior dashboard or simply with adhesive tape 5 For installation of the sensor in the position of the thermo...

Page 6: ...ating cooling system INSTALLING THERMAL SWITCH Part 0401 OR 0444 1 Install the Thermo Switch Part 0401 or Part 0444 Refer Wiring Diagrams Figure 1 and Figure 2 below 2 For detailed instructions on installing switches please refer to 0401 0444 instruction sheets 3 Bleed the EWP Refer to SECTION 4 BLEEDING THE EWP Page 9 After bleeding the EWP continue on with the next stage WARNING ENSURE IGNITION ...

Page 7: ...PG conversion This option will provide maximum flow from your EWP under all operating conditions without a Digital Controller or a Thermatic Switch fitted Should you choose this method you should retain the engine thermostat and drill one or two holes suggest 5mm in the plate to allow some coolant flow when the thermostat is closed Figure 3 Wiring Diagram EWP Continuous Running BATTERY _ VE IGNITI...

Page 8: ...ostat housing 3 Re fit the thermostat housing ensuring that there is no damage to the thermostat housing gasket OR 1 Remove the existing belt driven water pump housing 2 Remove the water pump impeller from the pump shaft NOTE You may need to drill holes through the impeller close to the drive shaft Alternatively remove vanes from impeller Mechanical water pumps differ from engine to engine and you...

Page 9: ...stem with appropriate coolant 2 Turn heater on full 3 With the radiator cap off hardwire the EWP directly to the vehicle s battery or a 12v power source Air trapped in the cooling system will exit at the top of the radiator 4 Turn on engine and idle 5 Top up the radiator with coolant with the EWP running until all air is eliminated Waterless coolants increase the load on an EWP and may reduce pump...

Page 10: ... months e g a show static display or race car it s strongly recommended the EWP is operated for approximately 5 mins constant running every month This will minimise the build up of any sediment in the EWP and also lubricate all parts within the pump Heater For improved heater performance on vehicles which have the heater inlet return and outlet ports in the mechanical pump housing referred to in W...

Page 11: ...oller Combo Kit must be a steady positive supply of 12 14V or 24 27V DC Vehicles with both heater circuit inlet return and outlet ports in the mechanical pump housing will suffer reduced heater performance unless the heater returns position is relocated The engine cooling system must use coolant as specified by the vehicle s manufacturer The EWP is a circulation pump ideal for most closed circuit ...

Page 12: ...asonably necessary to correct any fault in the operation of your Electric Water Pump provided that such a fault is directly attributable to a defect in the workmanship or materials used in the manufacture of the part s and is not due to installation other than described in these instructions Labour and consequential costs are excluded DAVIES CRAIG PTY LTD REGISTER YOUR WARRANTY AT www daviescraig ...

Reviews: