After aligning and focusing the measuring 

tool, read the heights at both levelling 

rods. Calculate the difference d between
the height 

a

1

 of levelling rod 

A

 and the 

height 

b

1

 of levelling rod 

B

.

Example:

  a

1

 = 1.937m

  b

1

 = 1.689m

  a

1

 – 

b

1

 = 1.937m– 1.689m = 0.248m=d

B

A

100’

(30 m)

a

1

b

d

1

B

A

3’

(1 m)

a

2

b

2

d

350

340

0

10

50

40

30

a

2

 – d = b

2

a

1

 – b

1

 = d

Set up the measuring tool approx. 6 ft (2 

m) away from levelling rod 

A

. After aligning 

and focussing the measuring tool, read 

the height 

a

2

 at levelling rod 

A

.

Subtract the previously calculated value 

d from the measured height 

a

2

 in order to 

receive the set value for the height 

b

2

 at 

levelling rod 

B

.

Measure height 

b

2

 at levelling rod 

B

When the measured value deviates by 

more than 3 mm (AL8-26) or 2 mm (AL8-

32) from the calculated set value, the 

crosshair must be readjusted.

Example:
  

a

2

 = 1.724m

  

d

 =0.248m

  

a

2

 – 

d

 = 1.724 m – 0.248 m = 1.476m

AL8-26: When measuring, height 

b

2

 must 

be 1.476 m ±3 mm.
AL8-32: When measuring, height 

b

2

 must 

be 1.476 m ±2 mm.

Readjusting the Crosshair

B

A

100’

(30 m)

a

1

b

d

1

B

A

3’

(1 m)

a

2

b

2

d

350

340

0

10

50

40

30

a

2

 – d = b

2

a

1

 – b

1

 = d

Unscrew the eyepiece cover 

5

. Using 

the adjusting pin 

18

, turn adjusting 

screw 5 clockwise or anticlockwise, 

until the calculated set value for height 

b

2

 is reached when measuring on 

levelling rod 

B

.

Screw on eyepiece cover 

5

 again.

Summary of Contents for AL8-26

Page 1: ...AL8 Series Owner s Guide www davidwhite com FOR CUSTOMER SERVICE PARTS AND REPAIR CALL 765 581 4097 IMPORTANT IMPORTANT IMPORTANTE Read Before Using Lire avant usage Leer antes de usar AL8 26 AL8 32 ...

Page 2: ...xtremely rugged field use Like all precision instruments however they should be treated with reasonable care to prolong life and accuracy All instruments are adjusted when they are shipped from the factory It is the customer s responsibility to check and to ensure instruments are adjusted prior to using David White is not responsible for errors caused by instruments that are out of adjustment Cont...

Page 3: ... 3 13 5 10 11 13 12 9 14 7 15 16 1 15 13 8 4 2 3 17 18 19 6 ...

Page 4: ...just to the ambient temperature before putting it into operation In case of extreme temperatures or variations in temperature the accuracy of the instrument can be impaired Avoid any impact to or dropping of the instrument After severe exterior effects to the instrument it is recommended to carry out an accuracy check each time before continuing to work Place the instrument in the provided case wh...

Page 5: ... 14 Tripod mount 5 8 on the rear side 15 Horizontal drive screw 16 Focusing knob 17 Allen key 18 Adjusting pin 19 Plumb bob Technical Data AL8 Series AL8 26 AL8 32 Accuracy 1 16 100 1 6mm at 30m 1 32 100 1 0mm at 30m Working Range 300 90m 400 120m Clear obj aperture 1 4 36 mm 1 6 40mm Setting accuracy 0 8 0 3 Deviation for 1 km double run leveling 1 5 mm 1 0 mm Telescope Magnification 26 x 32 x Im...

Page 6: ...G It is important that the tripod is set up firmly Make sure that the tripod points are well into the ground On paved surfaces be sure the points hold securely The legs should have about a 3 1 2 foot spread positioned so the top of the tripod head appears level If using a tripod with adjustable legs be sure the leg clamps are securely hand tightened Attach the instrument to the tripod securely han...

Page 7: ... crosshair appears sharp and deep black Direct the telescope towards the levelling rod if required with help of the optical peep sight 2 Turn the focusing knob 15 until the graduation field of the levelling rod appears sharp Align the crosshair exactly with the center of the leveling rod by turning the horizontal drive screw 14 When the telescope is correctly focussed the crosshair and the image o...

Page 8: ...ting the Circular Bubble Vial Bring the air bubble of the circular bubble vial 8 in a position between the centre and the end position of the check by turning the levelling screws 13 A 100 30 m a1 A 3 1 m a2 a2 d a1 b1 Using the Allen key 17 turn the adjusting screws 12 until the air bubble is positioned in the centre of the circular bubble vial B A 100 30 m a1 d B A 3 1 m a2 d a2 d b2 a1 b1 d Che...

Page 9: ...ured height a2 in order to receive the set value for the height b2 at levelling rod B Measure height b2 at levelling rod B When the measured value deviates by more than 3 mm AL8 26 or 2 mm AL8 32 from the calculated set value the crosshair must be readjusted Example a2 1 724m d 0 248m a2 d 1 724 m 0 248 m 1 476m AL8 26 When measuring height b2 must be 1 476 m 3 mm AL8 32 When measuring height b2 m...

Page 10: ...thorized after sales service center for Dave White s SitePro instruments In all correspondence and spare parts orders please always include the model number and serial number of the instruments All precision instruments should be cleaned lubricated checked and adjusted ONLY at a qualified instrument repair station or by the manufacturer at least once a year In case of repairs send in the instrumen...

Page 11: ... 90 DAY LIMITED WARRANTY To make a claim under this Limited Warranty you must return the complete product transportation prepaid For details to make a claim under this Limited Warranty please visit www davidwhite com or call 1 855 354 9881 ANY IMPLIED WARRANTIES SHALL BE LIMITED IN DURATION TO ONE YEAR FROM DATE OF PURCHASE SOME STATES IN THE U S AND SOME CANADIAN PROVINCES DO NOT ALLOW LIMITATION...

Page 12: ...42345D8932 09 15 Printed in China Dave White s SitePro 7619 S 1150 E Otterbein IN 47970 Tel 1 765 581 4097 ...

Reviews: