background image

 

 

 

 

6 of 10

 

 

19541P-42 (03-12)

 

 

Range 

The range of a belt station and a gateway can be up to 300 ft (100m).  If you are in an 
environment with metal or concrete walls, this range could be reduced.  If the belt station enters 
into a "fringe" reception area, a brief sequence of three beeps will be heard in the headset.  This 
is to serve as a warning of a possible disconnection if conditions are not improved.  When 
possible, the user should attempt to regain light-of sight contact with the controller.  When the 
belt station travels out of range of the gateway, a voice alert will indicate that the connection has 
been lost.  To reconnect, simply move back into range and connection with the gateway will 
automatically be reestablished, also noted by a voice alert.  
 

 

P

P

u

u

r

r

g

g

i

i

n

n

g

g

 

 

 
In some circumstances it may be necessary to “purge” the U9921-GUV of some of its linked belt 
stations.  Typically purging is not necessary unless there are multiple gateways in the same 
vicinity and you wish to remove a belt station from this gateway and link to a different gateway.  
A gateway can link up to six belt stations where a belt station can be linked to only one gateway 
at a time.   
 
 

Smart Purge 

smart purge

 is the purge method employed for the U9921-GUV, in which only unwanted links 

are removed from the gateway.  When this procedure is complete, only belt stations that are 
connected to the gateway remain linked.  All other belt station links will have been removed (see 
the belt station User Manual for the individual belt station purging procedure when remaining 
link purging may be necessary.) 
 

Smart Purge procedure 
 

1.

 

Ensure the gateway is powered on and functioning. 

2.

 

Disconnect all belt stations to be purged (power off the belt stations). 

3.

 

Verify the number of green LED flashes on the gateway matches the number of 
belt stations to be kept linked. 

4.

 

Press and hold LINK button on the gateway for 30 seconds until LED quickly 
flashes red. 

5.

 

Release LINK button. 

 

 

Summary of Contents for U9921-GUV

Page 1: ...19541P 42 03 12 2012 DAVID CLARK COMPANY INCORPORATED USER MANUAL Universal Gateway U9921 GUV P N 40994G 01 ...

Page 2: ......

Page 3: ...g damage If damage is apparent immediately file a claim with the carrier and notify your David Clark product supplier ELECTRICAL HAZARD Disconnect electrical power when making any internal adjustments or repairs All repairs should be performed by a representative or authorized agent of the David Clark Company STATIC HAZARD Static electricity can damage components Therefore be sure to ground yourse...

Page 4: ...992G 01 or U9912 BSW 40992G 02 Wireless Belt Stations becomes part of a wireless intercom system The U9921 GUV provides communication for up to four users as well as an interface to an existing wired intercom system Up to four belt stations can be connected to one gateway Status LED Gasket Bracket Nut Panel Antenna Connection Threaded Post Interface Connector LINK VOL R Figure 1 Overview of Gatewa...

Page 5: ...ments for the corresponding intercom Mounting The U9921 GUV may be flush mounted or surface mounted using the included gasket nut and bracket See Figure 1 for mounting suggestions Note Bracket P N 41045G 01 optional Not used for flush mount applications Bracket mounting configuration may be reversed for varying requirements e g vehicle dash vs ceiling mount See Appendix A for Mounting Templates An...

Page 6: ...he U9921 GUV and the LINK PTT button on the belt station to link with 3 Amber LED s will flash on both devices A momentary red LED indicates a successful close link 4 Upon successful link the U9921 GUV will attempt to establish a connection with the belt station 5 Upon successfully establishing connection the LED on the controller will flash a green pattern corresponding to the number of belt stat...

Page 7: ... over the two way radio simultaneously For more information consult the user manual for the belt station Tip Wireless users who are not pressing PTT while another wireless user is pressing PTT will not be heard on the wired intercom while the PTT remains pressed Intercom Level Adjustment Audio levels can vary between intercoms mainly due to the system level setting on the wired intercom To compens...

Page 8: ...Typically purging is not necessary unless there are multiple gateways in the same vicinity and you wish to remove a belt station from this gateway and link to a different gateway A gateway can link up to six belt stations where a belt station can be linked to only one gateway at a time Smart Purge A smart purge is the purge method employed for the U9921 GUV in which only unwanted links are removed...

Page 9: ...3800 Vehicular Intercom System C99 22MS 40935G 08 U9800 Marine Intercom System C99 20CX 40935G 07 U9500 Marine Intercom System C99 20LL 40935G 06 U3400 Portable Intercom System U3100 Modular Intercom System C99 20MS 40935G 05 Whip Antenna P N 40688G 92 Remote Antenna Kit Mag Mount P N 40688G 93 Remote Antenna Kit Permanent P N 40688G 96 Mounting Bracket Kit P N 41045G 01 C Ca ar re e a an nd d M M...

Page 10: ...nd can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the us...

Page 11: ...David Clark Company Inc could void the users authority to operate the equipment F FC CC C R Ra ad di ia at ti io on n E Ex xp po os su ur re e S St ta at te em me en nt t This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20 centimeters 8 inches between the radiator antenna ...

Page 12: ......

Page 13: ...19541P 42 05 11 10 of 10 Appendix A Mounting Templates Figure A1 Flush Mount Figure A2 Bracket Mount Optional P N 41045G 01 ...

Reviews: