19545P-98 (03-14)
6 of 6
Troubleshooting
No Status LED
•
No battery inserted into bay
•
Battery inserted incorrectly (see
Figure 1
)
•
Power Supply not connected to charger
•
Line cord not connected to power supply
•
Line cord not connected to AC mains
•
Disconnect and reconnect Line cord
Red Status LED
•
See
Error/Protection States
section above
•
Discard/recycle damaged batteries
Accessories
•
C99-14AC1 (P/N 41090G-14): AC line cord and power adapter for North/Central/South America
(110 VAC)
•
C99-14AC2 (P/N 41090G-15): AC line cord and power adapter for Europe, Middle East, Africa
and Asia/Pacific (250 VAC)
•
C99-14DC1 (P/N 41090G-16): DC cable for mobile/vehicle applications (5-15VDC, 5A)
•
C99-14DC2 (P/N 40688G-98): DC converter/cable kit for mobile/vehicle
applications (8-28VDC, 5A)
Specifications
Input Voltage:
5 to 15 VDC
Input Current:
5 A (max)
Output Voltage:
4.2 VDC
Output Current:
850mA per battery (max), 4A total (max)
Operating Temperature:
0°C (32°F) – 38°C (100°F)
Product Dimensions:
12 cm X 8 cm X 9 cm (4.75 in X 3.25 in X 3.5 in)
Charge Bays:
4
Battery Compatibility:
Li-Polymer 3.7V, 2260mAh (P/N: 40688G-90)
Summary of Contents for A99-14CRG