background image

 

 

 

 

10

 

of

 

11

 

 

19541P

39

 

(02

11)

 

may

 

cause

 

harmful

 

interference

 

to

 

radio

 

communications.

  

However,

 

there

 

is

 

no

 

guarantee

 

that

 

interference

 

will

 

not

 

occur

 

in

 

a

 

particular

 

installation.

  

If

 

this

 

equipment

 

does

 

cause

 

harmful

 

interference

 

to

 

radio

 

or

 

television

 

reception,

 

which

 

can

 

be

 

determined

 

by

 

turning

 

the

 

equipment

 

off

 

and

 

on,

 

the

 

user

 

is

 

encouraged

 

to

 

try

 

to

 

correct

 

the

 

interference

 

by

 

one

 

or

 

more

 

of

 

the

 

following

 

measures:

 

 
‐ 

Reorient

 

or

 

relocate

 

the

 

receiving

 

antenna.

 

‐ 

Increase

 

the

 

separation

 

between

 

the

 

equipment

 

and

 

the

 

receiver.

 

‐ 

Connect

 

the

 

equipment

 

into

 

an

 

outlet

 

on

 

a

 

circuit

 

different

 

from

 

that

 

to

 

which

 

the

 

receiver

 

is

 

connected.

 

‐ 

Consult

 

the

 

dealer

 

or

 

an

 

experienced

 

radio/TV

 

technician

 

for

 

help.

 

 
 

You

 

may

 

also

 

find

 

helpful

 

the

 

following

 

booklet,

 

prepared

 

by

 

the

 

FCC:

 

"How

 

to

 

Identify

 

and

 

Resolve

 

Radio

TV

 

Interference

 

Problems."

  

This

 

booklet

 

is

 

available

 

from

 

the

 

U.S.

 

Government

 

Printing

 

Office,

 

Washington

 

D.C.

 

20402.

 

 

*

 

In

 

order

 

to

 

maintain

 

compliance

 

with

 

FCC

 

regulations

 

shielded

 

cables

 

must

 

be

 

used

 

with

 

this

 

equipment.

  

Operation

 

with

 

non

approved

 

equipment

 

or

 

unshielded

 

cables

 

is

 

likely

 

to

 

result

 

in

 

interference

 

to

 

radio

 

&

 

television

 

reception.

 

 

I

I

n

n

d

d

u

u

s

s

t

t

r

r

y

y

 

 

C

C

a

a

n

n

a

a

d

d

a

a

 

 

S

S

t

t

a

a

t

t

e

e

m

m

e

e

n

n

t

t

 

 

 

This

 

device

 

complies

 

with

 

Industry

 

Canada

 

licence

exempt

 

RSS

 

standard(s).

 

Operation

 

is

 

subject

 

to

 

the

 

following

 

two

 

conditions:

 

(1)

 

this

 

device

 

may

 

not

 

cause

 

interference,

 

and

 

(2)

 

this

 

device

 

must

 

accept

 

any

 

interference,

 

including

 

interference

 

that

 

may

 

cause

 

undesired

 

operation

 

of

 

the

 

device.

 

 

 

U

U

n

n

a

a

u

u

t

t

h

h

o

o

r

r

i

i

z

z

e

e

d

d

 

 

C

C

h

h

a

a

n

n

g

g

e

e

s

s

 

 

 

Changes

 

or

 

modifications

 

not

 

expressly

 

approved

 

by

 

David

 

Clark

 

Company,

 

Inc.

 

could

 

void

 

the

 

users’

 

authority

 

to

 

operate

 

the

 

equipment.

 

 

 

U

U

s

s

a

a

g

g

e

e

 

 

R

R

e

e

s

s

t

t

r

r

i

i

c

c

t

t

i

i

o

o

n

n

s

s

 

 

 

US

 

Models

 

 

Due

 

to

 

the

 

UPCS

 

frequencies

 

used,

 

this

 

product

 

is

 

licensed

 

for

 

operation

 

only

 

in

 

the

 

United

 

States

 

of

 

America

 

and

 

Canada.

 

 

EU

 

Models

 

 

Due

 

to

 

the

 

DECT

 

frequencies

 

used,

 

this

 

product

 

is

 

licensed

 

for

 

operation

 

only

 

in

 

the

 

European

 

Union

 

countries.

 

 
 

Summary of Contents for 40992G-01

Page 1: ...19541P 39 02 11 2011 DAVID CLARK COMPANY INCORPORATED USER MANUAL Wireless Belt Station U9910 BSW U9910 BSW EU P N 40992G 01 P N 40992G 03 ...

Page 2: ......

Page 3: ...g damage If damage is apparent immediately file a claim with the carrier and notify your David Clark product supplier ELECTRICAL HAZARD Disconnect electrical power when making any internal adjustments or repairs All repairs should be performed by a representative or authorized agent of the David Clark Company STATIC HAZARD Static electricity can damage components Therefore be sure to ground yourse...

Page 4: ...equired per system Up to four belt stations can be connected to one controller gateway Model U9910 BSW Wireless Belt Station P N 40992G 01 VOX Adjust Headset Connector Power Button Status LED Battery Compartment Battery Release Screw Link PTT Button Figure 1 Overview of Belt Station L Li in nk ki in ng g Before a belt station and a controller gateway can be connected they must first be linked As a...

Page 5: ...d to four of those six at one time Tip Once linked the devices will not need to be linked again unless they are purged see Purging Units may be special ordered that do not have persistent links S St ta at tu us s I In nd di ic ca at ti io on ns s The power button has a multi color LED in the center which serves as a status indication for the belt station Table 1 below lists these states Table 1 LE...

Page 6: ...d and then turn off The belt station is now powered down Auto Shut off Additionally the belt station will automatically power down if it is disconnected from its gateway controller for more than 30 minutes Headset In order for the U9910 BSW to be used a David Clark H9900 series headset must be connected To connect the headset align the connectors as shown then push and turn clockwise see Figure 2 ...

Page 7: ... knob fully counter clockwise CCW Mic is hot VOX knob in between full CW and full CCW VOX enabled VOX Adjustment Procedure 1 Ensure that the belt station is linked with a controller or gateway LED flashing green 2 Stand in the noisy environment where you will be using the system but do not speak 3 Turn VOX knob fully counter clockwise You will hear a continuous tone 4 While continuing not to speak...

Page 8: ...TT button allows the user to activate additional functionality such as to speak over a two way radio or to an aircraft intercom PTT will also override the VOX setting see VOX For more information see the user manual for the appropriate controller or gateway Low Battery Under typical conditions the battery in the belt station will last up to 24 hours or longer A voice alert will indicate to the use...

Page 9: ...9541P 39 02 11 6 A voice alert will indicate that the connection has been deleted When this procedure is complete the belt station will not automatically connect to a controller gateway and must be linked again ...

Page 10: ...rt Battery with Contacts Down Lift Door Figure 4 Battery Insertion Removal T Tr ro ou ub bl le es sh ho oo ot ti in ng g Table 3 Troubleshooting Problem Solution Controller will not turn on Review Power up Power down procedure Ensure a fresh battery is installed Cannot link a belt station Review Linking procedure Ensure units are within 1 to 3ft 0 3 to 0 9m of each other No sidetone Not connected ...

Page 11: ...i ic ca at ti io on ns s Frequency Range 1920 MHz 1930 MHz U S and Canada 1880 MHz 1900 MHz EU Average RF Power Output 4 mW 100mW peak U S and Canada 10 mW 250 mW peak EU Range 300 ft 100m line of sight nominal Battery Life 24 hrs continuous use nominal Operating Temperature 14 F to 113 F 10 C to 45 C Storage Temperature 4 F to 140 F 20 C to 60 C Power Requirements 3 7V 100mA nominal Battery Type ...

Page 12: ...ngton D C 20402 In order to maintain compliance with FCC regulations shielded cables must be used with this equipment Operation with non approved equipment or unshielded cables is likely to result in interference to radio television reception I In nd du us st tr ry y C Ca an na ad da a S St ta at te em me en nt t This device complies with Industry Canada licence exempt RSS standard s Operation is ...

Page 13: ...ement known as the Specific Absorption Rate or SAR Tests for SAR are conducted using standardized methods with the product transmitting at its highest certified power level in all used frequency bands The product is designed to meet the relevant guidelines for exposure to radio waves SAR data information for residents in countries that have adopted the SAR limit recommended by the International Co...

Reviews: