Verifications prior to initial start-up

After making the connections defined in the preceding section, 

unscrew the filter cover and fill the pump prefilter with water to 

the bottom level of the suction line. Verify that the pump shaft 

turns freely.

Verify that the mains voltage and frequency match those 

specified on the nameplate of the pump.

Set the prefilter cover back in place and screw it to a suitable tightness. 

Check that the turning direction of the motor matches that specified on the 

fan cover. In three phase motors, if the turning direction is incorrect, reverse 

two supply phases on the protection panel.
If the motor does not start, try to determine the cause of the irregularity by 

consulting the list of common faults and their possible solutions, provided in 

this manual. NEVER RUN THE PUMP DRY.

Starting

Open all the gate valves and put the motor under voltage. Wait a 

reasonable time to allow self-priming. Verify the breakaway current and 

suitable adjust the thermal relay.

Maintenance

WARNING: Ensure that the pump is switched off from the 

supply mains before removing the cover.

Pumps are not to be plugged permanently to the supply voltage.

Our pumps do not require any specific maintenance. It is advisable, however, 

to periodically clean the pump filter and to empty the pump housing in low 

temperature periods through the blow off plug. If the pump is to remain idle, 

it is advisable to empty and clean it, and then reinstall the filter cover with 

oring lubricant on the rubber gasket, taking measures to ensure that the place 

where the pump is to be stored will remain dry and ventilated.
In the event of breakdown, the user must in no event handle the pump,  

Summary of Contents for WHISPER Series

Page 1: ...s may cause serious bodily injury and or property damage The installation of this product should be carried out by a person knowledgable in swimming pool plumbing requirements following the installation instructions provided in this manual Typhoon Whisper WHISPER Series TYPHOON C T Series Swimming Pool Pumps Installation and Operating Instructions ...

Page 2: ...of these installation and operating instructions please contact your Davey dealer or the appropriate Davey office as listed on the back of this document The Davey Whisper and Tyhoon pool pumps have been designed to circulate swimming pool and spa water in conditions set out in the Australian Standard for swimming pool water quality AS 3633 or equivalent They should not be used for any other purpos...

Page 3: ...lt consequences for which we decline all responsibility Installation The installation of our electric pumps is only permitted in swimming pools or ponds that meet DIN standards VDE 0100 part 702 11 82 In case of doubt inquire with an expert The pump should be installed as near as possible to water level in horizontal position in order to obtain a minimum suction path and reduce head losses It is n...

Page 4: ...ld be structured with a slight slant to prevent the formation of siphons Electrical connection IMPORTANT INFORMATION Your Davey pump is Double Insulated to Water Circuit If equipotential bonding structure is required then a Equipotential Bonding Point is provided Please refer to your local statutes and regulations for AS NZ 3000 Wiring standards The electrical installation should have a multiple s...

Page 5: ...nd their possible solutions provided in this manual NEVER RUN THE PUMP DRY Starting Open all the gate valves and put the motor under voltage Wait a reasonable time to allow self priming Verify the breakaway current and suitable adjust the thermal relay Maintenance WARNING Ensure that the pump is switched off from the supply mains before removing the cover Pumps are not to be plugged permanently to...

Page 6: ...p it contains no toxic or contaminating materials The principal components are duly identified for selective breaking If the supply cord is damaged it must be replaced by the manufacturer or it s service agent or a similarly qualified person in order to avoid a hazard SINGLE PHASE SUPPLY Fig 1 ...

Page 7: ...prime 2 Pump supplies scant flow 3 Pump noisy 4 Pump does not start 5 Motor makes sound but does not start 1 2 3 4 5 Problem Solution X X Air entry through suction line Verify condition of connectors and gaskets of suction linw X Inadequate airtightness of filter cover Clean the filter cover and verify condition of rubber gasket X X Motor turning direction reversed Reverse 2 phases of the supply X...

Page 8: ...ty The warranty claim will be assessed by Davey on the basis of their product knowledge and reasonable judgement and will be accepted if a relevant defect is found the warranty claim is made during the relevant warranty period and none of the excluded conditions listed above apply The customer will be notified of the warranty decision in writing and if found to be invalid the customer must organis...

Reviews: