Extra Draw-off Capacity

The Torrium2 controller has an in-built accumulator which will 

accommodate small leaks.  In some applications it may be appropriate to 

install additional accumulator (Supercell pressure tank) capacity.  These 

applications includes:

•   Long suction lines (see Suction Lines / Lift)

•   Low flow appliances connected to the pump, such as evaporative air 

conditioners, slow filling toilet cisterns, etc.

Any additional accumulators can be installed either in place of the priming 

plug (see Figure 1) for tanks up to 20 litres total capacity, or for larger 

tanks, downstream of the controller (ie. between the controller and the first 

outlet).

Where extra draw-off capacity is utilised the additional pressure tank 

should have a pre-charge of 70% of the maximum system (shut-off) 

pressure.

Evaporative coolers, RO filters and extra draw-off 
capacity

Where a Torrium2 equipped pump is required to supply water to an 

evaporative cooler, reverse osmosis (R.O.) filter or similar low flow device, 
the Torrium2 will detect the limited demand. This will result in the Torrium2 

adapting to the slow demand. The pump start pressure will be allowed 

to drop to a lower cut in pressure each time low flows are detected. To 

provide the maximum draw-off from the additional pressure tank, the tank’s 

pre-charge should be set at 45% of the pump shut-off pressure.

If normal flow is required from your system, Torrium2 will initiate instant start.

Fit the Supercell pressure tank (up to 20 litres total capacity) to the tank 

connection/priming port 

with thread tape and pipe socket

. Firmly 

hand 

tighten. For larger tanks, these should be installed downstream of the 

controller.

NOTE: If fitting a tank to the priming port, you may require a 1” 
BSP socket, since both Torrium2 prime port and tank are 1” male 
threads.

DO NOT USE THREAD SEALING COMPOUNDS, HEMP OR PIPE DOPE!

Trouble Shooting Check List

a)  PUMP HAS STOPPED OR MOTOR RUNS FOR SHORT PERIOD 

ONLY WHEN SWITCHED ON OR PRIME BUTTON PUSHED, 
BUT DOES NOT PUMP - YELLOW STATUS INDICATOR LIGHT 
ILLUMINATED

 

1.  Suction line and pump body not filled with water.

 

2.  Air leaks in suction lines or suction pipe not under water.

 

3.  Air trapped in suction lines (also possible with flooded suction due to 

uneven rise in piping; eliminate humps and hollows).

 

4.  No water at source or water level too low.

 

5.  Valve on suction lines closed. Open valve & pump will restart 

automatically or press “Prime” button.

b)  PUMP SWITCHES ON AND OFF FREQUENTLY (CYCLING)

 

1.  Cycling may occasionally be caused by float valves filling tanks.

 

2.  Leaking taps, float valves etc. check plumbing.

 

3.  Leaking check valve/foot valve.

c)  MOTOR DOESN’T START WHEN SWITCHED ON - INDICATOR 

LIGHTS NOT ILLUMINATED

 

1.  Power not connected or no power available from supply outlet.

d)  MOTOR STOPS - YELLOW STATUS INDICATOR LIGHT IS 

ILLUMINATED

 

1.  Motor ”over temperature” cut-out tripped. Consult Davey dealer.

 

2.  Motor not free to turn - e.g. a jammed impeller. Consult Davey 

dealer.

 

3.  Prime button has been held in for too long. Release prime button 

and switch off power for 1 minute to allow unit to reset.

 4. 

Your Torrium2 has detected high water temperature in the pump.  
Once the water has cooled the Torrium2 will automatically restart  
the pump.

e)  PUMP WILL NOT STOP

 

1.  Water leaks on discharge side of pump.

f)  PUMP WILL OPERATE NORMALLY INITIALLY BUT WILL NOT 

RESTART ON WATER DEMAND - STATUS INDICATOR LIGHT NOT 
ILLUMINATED

 

1.  Power supply problem - see c) 1.

g)  PUMP WILL OPERATE NORMALLY INITIALLY BUT WILL NOT 

RESTART ON WATER DEMAND - YELLOW STATUS INDICATOR 
LIGHT IS ILLUMINATED

 

1.  Suction air leak - pump has partially lost prime.

 

2.  Blocked impellers or suction.

 

3.  Discharge valve closed - open valve.

Summary of Contents for Torrium2

Page 1: ...difficulties or if the product is faulty or defective advise you on how to have your Davey product repaired obtain a replacement or a refund Your Davey Two Year Guarantee naturally does not cover nor...

Page 2: ...Before installing your Torrium2 controller please read all instructions carefully as failures caused by incorrect installation or operation are not covered by the guarantee Your Torrium2 controller is...

Page 3: ...60Hz models use suffix Y USA and 220 240V 60Hz models use suffix P USA Fitment of the Torrium2 controller The Torrium2 controller fits onto the outlet of the pump The Torrium2 controller is designed t...

Page 4: ...able to be used as a discharge port During servicing use only approved non petrochemical based oring and gasket lubrication If unsure consult your Davey Dealer for advice WARNING Do not use hydrocarbo...

Page 5: ...socket since both Torrium2 prime port and tank are 1 male threads DO NOT USE THREAD SEALING COMPOUNDS HEMP OR PIPE DOPE Trouble Shooting Check List a PUMP HAS STOPPED OR MOTOR RUNS FOR SHORT PERIOD ON...

Page 6: ...er access to the inbuilt check valve in the Torrium Davey suggest you use a flexible connection and or union connection to allow for ease of access to the check valve Pipe Connections For best perform...

Page 7: ...we are obliged to inform you that this appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they ca...

Page 8: ...Water return mode will restart the pump automatically if the Torrium2 detects water flow through it Electrical Power Surge Protection An electrical power surge or spike can travel on the supply lines...

Reviews: