Auto-retry and Water Return Modes

Should your Torrium2 detect a loss of prime, after stopping the pump, it will wait five 

minutes before activating Auto-retry and Water Return modes.  Auto-retry automatically 

starts the pump to see if the pump is now primed.  

It does this after 5 mins, 30 mins, 1 hr, 2 hrs, 8 hrs, 16 hrs and 32 hrs.  Water return mode 

will restart the pump automatically if the Torrium2 detects water flow through it.

Electrical Power Surge Protection

An electrical power surge or spike can travel on the supply lines and cause serious 

damage to your electrical equipment. The Torrium2 controller  has a metal oxide varistor 

(MOV) fitted to help protect it’s circuit. The MOV is not a lightning arrestor and may not 

protect the Torrium2 controller if lightning or a very powerful surge hits the pump unit.
If the installation is subject to electrical power surges or lightning we strongly recommend 

the use of a suitable surge protection device on ALL electrical equipment.

Surge Protector Status Window

To allow you to check the status of the inbuilt MOV in the Torrium2 there is a viewing 

window at the back of the Torrium2 above the power lead entry / exit grommet. The MOV is 

the blue disc shaped component. Should it be consumed due to power spikes it will almost 

always blacken the viewing port. This will indicate a non-warrantable failure.

WARNING: Automatic reset thermal overloads may allow the pump to restart 

without warning. Always disconnect the pump motor from the electrical supply 

before maintenance or repairs.

WARNING: When servicing or attending pump and/or controllers, always ensure 

power is switched off and lead unplugged. Electrical connections should be ser-

viced only by qualified persons.

Care should also be taken when servicing or disassembling pump to avoid possible 

injury from hot pressurised water. Unplug pump, relieve pressure by opening a tap 

on the discharge side of the pump and allow any hot water in the pump to cool 

before attempting to dismantle.

IMPORTANT:

DO NOT USE petroleum based fluids or solvents (e.g. Oils, Kerosene, 

Turpentine, Thinners, etc) on the plastic pump components or seal components.

 

WARNING: Do not use hydrocarbon based or hydrocarbon propelled

 

sprays around the electrical components of this controller.

 

Abrasive Materials

 

The pumping of abrasive materials will cause damage to the

 

Torrium2 controller which will then not be covered by the guarantee.

NOTE: For protection, the Davey pump motors are fitted with an automatic reset 

thermal overload, constant tripping of this overload indicates a problem e.g. low 

voltage at pump, excessive temperature (above 50°C) in pump enclosure.

Summary of Contents for Torrium 2 TT45

Page 1: ...lieved Failure to observe this warning will expose persons to the possibility of personal injury and may also result in damage to the pump pipework or other property WARNING Failure to follow these in...

Page 2: ...pump run out of water or overheat should the pump fail to start due to low voltage or a blockage in the pump 3 Provides an easy to understand visual representation of the system status 4 Has adaptive...

Page 3: ...s commonly used worldwide special models with power leads to suit particular regions or countries are made For example for North America 110 120V 60Hz models use suffix Y USA and 220 240V 60Hz models...

Page 4: ...s thread sealing tape may be needed Fitting the P No 32574 adaptor flange for adapting to earlier Hydrascan and Torrium flanges First fit the Torrium2 controller with the adaptor flange using a thread...

Page 5: ...e suction line and footvalve NOTE The check valve minus the o ring needs to be replaced in the Torrium2 controller to properly direct water flow over the flow sensor Removing the o ring from the inbui...

Page 6: ...onnection must be incorporated in the fixed wiring in accordance with the wiring rules The electrical connections and checks must be made by a qualified electrician and comply with applicable local st...

Page 7: ...se consult your Davey Dealer for assistance Where the Davey pump involved has not had a controller fitted before use the wiring details below as a guide After half an hour of constant running Torrium2...

Page 8: ...t Should it be consumed due to power spikes it will almost always blacken the viewing port This will indicate a non warrantable failure WARNING Automatic reset thermal overloads may allow the pump to...

Page 9: ...disassembled Failure to observe this warning will expose persons to the possibility of personal injury and may also result in damage to other property Do not dismantle no user serviceable parts spring...

Page 10: ...s a problem e g low voltage at pump excessive ambient temperature above 50 C in pump enclosure b The Torrium2 control device may have to be reset after rectifying any of the above operating troubles T...

Page 11: ...ustomer from the service center at Davey s cost 3 This guarantee is subject to due compliance by the original purchaser with all directions and conditions set out in the In stallation and Operating In...

Page 12: ...g the product to the place of purchase is at your cost and is your responsibility The warranty claim will be assessed by Davey on the basis of their product knowledge and reasonable judgement and will...

Reviews: