background image

19

DAVEY GUARANTEE

Davey Repair or Replacement Guarantee

In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction 
within warranty periods beginning from the date of original purchase due to faulty materials or 
manufacture, Davey will at our option repair or replace it for you free of charge, subject to the 
conditions below.

Should you experience any difficulties with your Davey product, we suggest in the first instance that 
you contact the Davey Dealer from which you purchased the Davey product. Alternatively you can 
phone our Customer Service line on 1300 367 866 in Australia, or 0800 654 333 in New Zealand, or 
send a written letter to Davey at the address listed below. On receipt of your claim, Davey will seek to 
resolve your difficulties or, if the product is faulty or defective, advise you on how to have your Davey 
product repaired, obtain a replacement or a refund.

Your Davey Guarantee naturally does not cover normal wear or tear, replacement of product 
consumables (i.e. mechanical seals, bearings or capacitors), loss or damage resulting from misuse 
or negligent handling, improper use for which the product was not designed or advertised, failure to 
properly follow the provided installation and operating instructions, failure to carry out maintenance, 
corrosive or abrasive water or other liquid, lightning or high voltage spikes, or unauthorized persons 
attempting repairs.  Where applicable, your Davey product must only be connected to the voltage 
shown on the nameplate.

Your Davey Guarantee does not cover freight or any other costs incurred in making a claim. Please 
retain your receipt as proof of purchase; you 

MUST

 provide evidence of the date of original purchase 

when claiming under the Davey Guarantee. 

Davey shall not be liable for any loss of profits or any consequential, indirect or special loss, damage 
or injury of any kind whatsoever arising directly or indirectly from Davey products. This limitation 
does not apply to any liability of Davey for failure to comply with a consumer guarantee applicable to 
your Davey product under the Australian or New Zealand legislation and does not affect any rights or 
remedies that may be available to you under the Australian or New Zealand Consumer Legislation.

In Australia, you are entitled to a replacement or refund for a major failure and for compensation for 
any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or 
replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Should your Davey product require repair or service after the guarantee period; contact your nearest 
Davey Dealer or phone the Davey Customer Service Centre on the number listed on following page.

For a complete list of Davey Dealers visit our website (davey.com.au) or call.

Davey Guarantee Period

 Rainbank - Three Years

Summary of Contents for RainBank Evolution MkII

Page 1: ...INSTALLATION OPERATION TROUBLE SHOOTING INSTALLATION INSTRUCTIONS ATS 5200 477 Lic WMKA 22042 with Evolution MkII...

Page 2: ...icing specific and emerging market opportunities Many of these products have received multiple awards for innovation and excellence which have led to our induction into the Manufacturing Hall of Fame...

Page 3: ...Before you start 7 Installation instruction 8 How to install RainBank 9 Testing 11 Back Flow Prevention Requirements 12 Installation of Submersible Pumps and Priming 13 Maintaining RainBank 14 Trouble...

Page 4: ...ank can save up to 40 of your home s usage of mains water which could be up to 100 000 litres of water a year Your actual savings depend on your roof catchment area rainfall and the size of your tank...

Page 5: ...5 COMPONENTS Primary filter chamber Secondary filter chamber Dual check valve Inlet outlet connections Outlet isolation valve Mains isolation valve RainBank Outer Cover...

Page 6: ...4 If RainBank senses a water demand and detects insufficient water in the rainwater tank it will automatically allow the mains water to flow 5 If there is a power failure during a demand for water Ra...

Page 7: ...erformance and serviceability of your RainBank Fit a first flush system if possible to divert the initial run of water from the roof that may contain dirt and pollutants Fit a strainer to the top of y...

Page 8: ...rk containing rainwater is marked with green rainwater tape or stickers at 1 meter intervals and every outlet that may deliver rainwater is to be permanently signed with Rain Water signage or a green...

Page 9: ...t switch 3 Cut pump stand pipe so that pipe end is approximately 50mm from tank top in installed position 4 Connect a cable or chain to the submersible pump so that it can be lowered into the rainwate...

Page 10: ...g pattern 11 Reinstall the primary filter and lid 12 Connect Mains and outlet plumbing to Evolution MkII ensuring correct orientation If plumbing fit out is incorrect the use of flexible hoses is sugg...

Page 11: ...ompleted turn off tap NOTE Mains water indicator light is not applicable on this model 2 Fill the rainwater tank with sufficient water to activate or cover the pump 3 Check that the pump is correctly...

Page 12: ...flow valve you may be required to fit additional backflow protection valves to satisfy this requirement check with your local council as to their guidelines on rainwater tank installation and backflow...

Page 13: ...pipe Float switch Pump Handle 2mm hole IMPORTANT Do not pull on power lead Fit a rope to handle for lowering and raising pump Submersible pumps inside tank Provided the pump is sitting in sufficient w...

Page 14: ...y re starts the motor when the temperature within the pump has dropped to a safe level Constant tripping of this switch indicates a problem e g Low voltage at pump etc This automatic thermal overload...

Page 15: ...restored 2 No water in tank Check water level in tank 3 Mains water supply not connected to RainBank RainBank system must have a pressurised water supply connected to inlet Press manual override butt...

Page 16: ...ebris is blocking inlet and or filters in or out of RainBank In order of most likely solution 1 Mains inlet stop valve closed open stop valve 2 RainBank blocked this is highly unlikely ensure 1 is che...

Page 17: ...fically excluded WARNING Water freezing inside the RainBank will damage the unit Locate your RainBank and pump so that they are not susceptible to freezing RainBank must be installed and serviced by a...

Page 18: ...the tank swarf can block valves RainBank and toilet valves 3 Check with local council plumbing teams for backflow requirements 4 Keep pipe work well braced as vibrations can become noisy 5 Fill rainw...

Page 19: ...d lightning or high voltage spikes or unauthorized persons attempting repairs Where applicable your Davey product must only be connected to the voltage shown on the nameplate Your Davey Guarantee does...

Page 20: ...ia 3179 Ph 1300 232 839 Fax 1300 369 119 Email sales davey com au Davey Water Products Pty Ltd Member of the GUD Group ABN 18 066 327 517 NEW ZEALAND Customer Service Centre 7 Rockridge Avenue Penrose...

Reviews: