Commissioning Filter

Refer to “operating instructions” below for 

safety warning

 and 

multiport valve 

control

 prior to the filter start-up. The pool should be slightly overfilled and the filter 

backwashed and then run on RINSE to prevent dust and fine particles in the media 

bed returning to the pool.
1.  Backwash the filter for up to 2 to 3 minutes, then stop the pump.

2.  Position the valve handle to “RINSE”.

3.  Start the pump and run until the water in the valve sight glass becomes clear.

4.  Stop the pump and position the valve handle to “FILTER”.

5.  Start the pump. The Filter is now in filtration mode.

6.  To determine the correct operating conditions, check the pressure gauge 

reading is 80kPa or below.  Record the clean operating pressure of your filter.

Operating Instructions

WARNING - FILTER OPERATES UNDER HIGH PRESSURE

•  

Ensure all lids / closures / clamps are correctly secured before 

operating system.

•  

Never adjust clamps or change valve settings with the system 

under pressure.

•  

Relieve all pressure from system before working on filter.

Multiport Valve Control

The flow of water through the filter is controlled by the multiport valve on the top 

of the filter tank. The handle on top of the valve can be moved to any one of six 

positions, which have the following functions:

Valve Position 

Function

FILTER 

Normal filtration and vacuuming through filter.

BACKWASH 

Clean the filter.

RINSE 

Used on initial filter start-up and after backwash to 

prevent dirt in the sand returning to the pool.

WASTE 

By-passes the filter; used for vacuuming to waste, or 

draining the pool.

RECIRCULATE 

By-passes the filter to circulating water to the pool or to 

boost spa jets.

CLOSED 

Shuts off all flow to the filter.  Do not run pump.

CAUTION:

Never shift the valve handle position while the pump is running.

Summary of Contents for EcoPure DEP2140

Page 1: ... installation of this product should be carried out by a person knowledgeable in swimming pool plumbing requirements following the installation instructions provided in this manual INSTALLATION AND OPERATING INSTRUCTIONS WARNING Failure to follow these instructions and comply with all applicable codes may cause serious bodily injury and or property damage ...

Page 2: ...tion the filter tank and pump on a level concrete slab or similar base with minimum dimensions of 900mm x 600mm 3 x 2 Do not use sand to level the concrete slab as it may wash away and cause vibration and inefficient performance Allow sufficient space around the filter for routine maintenance and provide for adequate filter drainage and pump ventilation Place the pump in position on the slab and l...

Page 3: ...er draining from the pool during maintenance FAILURE TO COMPLY WITH THE ABOVE CAUTIONS MAY RESULT IN FILTER DAMAGE NOT COVERED BY THE GUARANTEE Pipe Connections Use Teflon tape on all male threads Piping should be independently supported and not impose heavy loads on the filter or pump Use 40mm or 50mm 11 2 or 2 pipe from the pump to the skimmer box return pipe for the multiport valve to the pool ...

Page 4: ...R OPERATES UNDER HIGH PRESSURE Ensure all lids closures clamps are correctly secured before operating system Never adjust clamps or change valve settings with the system under pressure Relieve all pressure from system before working on filter Multiport Valve Control The flow of water through the filter is controlled by the multiport valve on the top of the filter tank The handle on top of the valv...

Page 5: ... necessary to clean or backwash the filter see section on Backwashing the Filter Backwashing the Filter When the filter gauge reading is 40 50kPa above the clean filter gauge reading cleaning or backwashing is required To perform the backwash operation 1 Shut off the pump Be sure to disconnect any automatic Vacuum Cleaner 2 Shift the valve handle to BACKWASH 3 Start the pump and run until the wate...

Page 6: ...ter backwashing Check for blocked or plugged lines which could restrict flow Large quantities of media returning to the pool One of the lower laterals may be damaged To correct this condition the media must be removed and the lateral replaced Pump is operating noisily Investigate for a possible air leak in the suction line blocked pipes or rubbish in the pump strainer basket Refer to pump manual I...

Page 7: ...e working condition These should be replaced every 3 to 4 years d Remove any obstructions or debris from the main drain cover e Ensure the skimmer baskets and the pump hair and lint pots are free of leaves and debris at least once a week f Remove obstructions and combustibles from around the pump motor g Make sure all wiring connections are clean and that all wiring and electrical equipment is in ...

Page 8: ...which the product was not designed or advertised failure to properly follow the provided installation and operating instructions failure to carry out maintenance corrosive or abrasive water or other liquid lightning or high voltage spikes or unauthorized persons attempting repairs Where applicable your Davey product must only be connected to the voltage shown on the nameplate Your Davey Guarantee ...

Reviews: