background image

12

b. Please check for any water leaks before starting your Davey heat pump.
c. For protection, your Davey heat pump is equipped with a time lag starting function, the fan will run 1 

minute earlier than the compressor on start-up, and it will stop running 1 minute later than the compressor 

when your heat pump is stopped.

d. If you notice any abnormal noises from your heat pump, please turn it off and contact Davey.

7. MAINTENANCE

Disconnect the power to the heat pump before any inspection, cleaning or service.

R32 Gas

Any maintenance on the refrigeration circuit including handling, installation, 

cleaning and servicing and disposal must be carried out by licensed personnel 

and in compliance with national gas regulations. 

1. Winterising your heat pump:

Winterising is required in conditions where any water inside the heater can drop below 0°C. In this 

situation, if not carried out, severe damage is likely to occur to the Davey heat pump.
a. Turn off the circuit breaker, or isolation switch;
b. Drain the Davey heat pump. Loosen all water connections;
c. Rinse the interior of the heat exchanger cylinder with a stream of tap water for about 15 minutes to 

remove any chlorine residue that could cause damage to the heat exchanger. 

d. Tilt the unit towards the back to remove all water from the unit.
e. Block water inlet and outlet with a cloth or plastic to prevent mice, or other animals from entering the unit.

WARNING: All water connections to the pool should be disconnected for winter to allow 

complete drainage of the Davey heat pump. The winterising must be done before air 

temperatures reach freezing point.

WARNING: The Davey heat pump should never be tilted more than 30-35º, even 

during transportation. Should this occur, allow the Davey heat pump to sit for 

4 hours before turning on.

2. Please clean this machine with household detergents or clean water, NEVER use gasoline, thinners or 

any similar fuel.

3. Always disconnect the Davey heat pump before:

Opening the access door;
Cleaning the cabinet, or evaporator.

Summary of Contents for DHP90

Page 1: ...Please pass on these instructions to the operator of this equipment Pool Heat Pump Installation and Operating Instructions...

Page 2: ...ANCE 7 4 1 Installation reminder 7 4 2 Wiring 9 4 3 Electric wiring diagram 9 4 4 References for protecting devices and cable specification 9 5 OPERATION GUIDANCE 10 5 1 Key function 10 5 2 Operation...

Page 3: ...appliance or an operating electric heater Do not pierce or burn Be aware that refrigerants may not contain an odour R32 Gas INSTALLATION REMINDERS The installation of any pipework should be kept to a...

Page 4: ...r outage happens during operation the heat pump will start when the power is restored c Please switch off the main power supply in lightening and storm weather to prevent from damage caused by lightni...

Page 5: ...ortant to ensure that the flow rate in set to the advised water flow rate in section 3 6 and that the pressure does not exceed 500kPa In accordance with AS NZS 60335 2 40 we are obligated to inform yo...

Page 6: ...0 19 1 38 0 26 1 80 0 33 2 50 0 38 2 90 0 49 3 80 0 65 4 84 Input power at 50 speed kW 0 51 0 7 0 95 1 1 1 44 1 84 Rated input current A 0 83 5 98 1 13 7 83 1 44 10 90 1 66 12 7 2 15 16 53 0 95 7 01...

Page 7: ...his heat through its heat exchanger to the pool water Your Davey heat pump should be installed in a well ventilated area WARNING Improper installation adjustment service maintenance or use can cause f...

Page 8: ...fastened the bracket must be strong enough and antirust treated 2 Please ensure 50cm of clearance around each side of the Davey heat pump or the efficiency of the heat pump will be reduced 3 Although...

Page 9: ...full disconnection of the power supply must be incorporated in the fixed wiring in accordance with the wiring rules 4 3 Electric wiring diagram a For power supply 230V 50Hz Distribution Box Power Sup...

Page 10: ...ark when it s locked 5 2 Operation Instruction a Screen Lock 1 Press for 3 seconds to lock or unlock the screen 2 Automatic Lock Period 30 seconds if no operation b Power On Press for 3 seconds to unl...

Page 11: ...ss to exit status check mode SYMBOL CONTENT UNIT C0 Inlet water temp C C1 Outlet water temp C C2 Ambient temp C C3 Exhaust temp C C4 Outer coil pipe temp C C5 Gas return temp C C6 Inner coil pipe temp...

Page 12: ...to occur to the Davey heat pump a Turn off the circuit breaker or isolation switch b Drain the Davey heat pump Loosen all water connections c Rinse the interior of the heat exchanger cylinder with a...

Page 13: ...avoided The area around the workspace should be sectioned off Ensure that all conditions within the area have been made safe by control of flammable material 3 Always check the work area with an appr...

Page 14: ...chlorine may react with the refrigerant and corrode the copper pipework If a leak is suspected all naked flames should be removed or extinguished If a leakage of refrigerant is found which requires b...

Page 15: ...outlet water Insufficient water flow protection 4 Eb Ambient temperature too high or too low protection 5 Ed Anti freezing reminder No Display Failure Code Description 1 E1 High pressure protection 2...

Page 16: ...mperature difference then either restart the heat pump or go back into standby The default setting is P2 To change these parameters please contact your nearest Davey dealer verter heat pump solution I...

Page 17: ...V 50Hz Customer prepare Power Supply 230V 50Hz Earthing Water pump 230V voltage 500W capacity Breaker fuse Customer prepare Breaker fuse Customer prepare Contactor Powercord 17 Customer remote control...

Page 18: ...18...

Page 19: ...nt Registration Register by e mail or third party application Android iOS a E mail registration Android please download from iPhone please download from 1 APP Download 2 Account registration 1 Registe...

Page 20: ...20 Please set family name and choose location of device Create Family b Register through third party application...

Page 21: ...21 APP Pairing a With Bluetooth 1 Please confirm that you re connected to Wi Fi and your Bluetooth is on 2 Click Add Device and then follow the instructions to pair device...

Page 22: ...d release After hearing Beep enter Wi Fi password in app During connection will flash Once the app connects to Wi Fi successfully will display b With Wi Fi 1 Please make sure you are connected to Wi F...

Page 23: ...r On Off Setting temperature Select Boost Silence Mode 2 For heat pump with Heating Cooling function Compressor speed Query C F switch Setting temperature Select Boost Silence Mode Compressor speed In...

Page 24: ...ather forecast is just for reference 2 App is subject to updates without notice After pairing if your family members also want to control the device please let your family members register InverGo fir...

Page 25: ...tor DHP3503 1 14 403771 Sensors full set 1 16 16294 R32 Compressor DHP130 1 16 16296 R32 Compressor DHP170 210 1 16 16304 R32 Compressor DHP280 1 16 16305 R32 Compressor DHP3503 1 16 16292 R32 Compres...

Page 26: ...26 NOTES...

Page 27: ...27...

Page 28: ...their product knowledge and reasonable judgement and will be accepted if a relevant defect is found the warranty claim is made during the relevant warranty period and none of the excluded conditions...

Reviews: