background image

– 4 –

NOTE:

Ensure pipework is connected to appropriately labelled multiport 

valve connections.

Commissioning Filter

Refer to “operating instructions” below for 

safety warning

 and 

multiport valve 

control

 prior to the filter start-up. The pool should be slightly overfilled and the filter 

backwashed and then run on RINSE to prevent dust and fine particles in the media 

bed returning to the pool.
1.  Backwash the filter for up to 2 to 3 minutes, then stop the pump.

2.  Position the valve handle to “RINSE”.

3.  Start the pump and run until the water in the valve sight glass becomes clear.

4.  Stop the pump and position the valve handle to “FILTER”.

5.  Start the pump. The Filter is now in filtration mode.

6.  To determine the correct operating conditions, check the pressure gauge 

reading is 80kPa or below.  Record the clean operating pressure of your filter.

Operating Instructions

WARNING - FILTER OPERATES UNDER HIGH PRESSURE

•  

Ensure all lids / closures / clamps are correctly secured before 

operating system.

•  

Never adjust clamps or change valve settings with the system 

under pressure.

•  

Relieve all pressure from system before working on filter.

Multiport Valve Control

The flow of water through the filter is controlled by the multiport valve on the top 

of the filter tank. The handle on top of the valve can be moved to any one of six 

positions, which have the following functions:

Valve Position 

Function

FILTER 

Normal filtration and vacuuming through filter.

BACKWASH 

Clean the filter.

RINSE 

Used on initial filter start-up and after backwash to 

prevent dirt in the sand returning to the pool.

WASTE 

By-passes the filter; used for vacuuming to waste, or 

draining the pool.

RECIRCULATE 

By-passes the filter to circulating water to the pool or to 

boost spa jets.

CLOSED 

Shuts off all flow to the filter.  Do not run pump.

Summary of Contents for CrystalClear DCC2540

Page 1: ...of this product should be carried out by a person knowledgeable in swimming pool plumbing requirements following the installation instructions provided in this manual INSTALLATION AND OPERATING INSTR...

Page 2: ...ble Position the filter tank and pump on a level concrete slab or similar base with minimum dimensions of 900mm x 600mm 3 x 2 Do not use sand to level the concrete slab as it may wash away and cause v...

Page 3: ...nts water draining from the pool during maintenance FAILURE TO COMPLY WITH THE ABOVE CAUTIONS MAY RESULT IN FILTER DAMAGE NOT COVERED BY THE GUARANTEE Pipe Connections Use Teflon tape on all male thre...

Page 4: ...he clean operating pressure of your filter Operating Instructions WARNING FILTER OPERATES UNDER HIGH PRESSURE Ensure all lids closures clamps are correctly secured before operating system Never adjust...

Page 5: ...ge reading as in 2 above it will be necessary to clean or backwash the filter see section on Backwashing the Filter Backwashing the Filter When the filter gauge reading is 40 50kPa above the clean fil...

Page 6: ...uipment This filter is designed to be used with Pool Spa water balanced in accordance with Langlier Saturation Index with a pH level of between 7 2 and 7 6 and is regularly treated with a chlorine san...

Page 7: ...working condition These should be replaced every 3 to 4 years d Remove any obstructions or debris from the main drain cover e Ensure the skimmer baskets and the pump hair and lint pots are free of le...

Page 8: ...which the product was not designed or advertised failure to properly follow the provided installation and operating instructions failure to carry out maintenance corrosive or abrasive water or other l...

Reviews: