Davey BT14-300 Installation And Operating Instructions Manual Download Page 11

11

10

Trouble Shooting Check List

a)  PUMP HAS STOPPED OR MOTOR RUNS FOR SHORT PERIOD ONLY 

WHEN SWITCHED ON OR PRIME BUTTON PUSHED, BUT DOES  

NOT PUMP - YELLOW STATUS INDICATOR LIGHT ILLUMINATED.

  1.  Suction line and pump body not filled with water.

  2.  Air leaks in suction lines or suction pipe not under water.

  3.  Air trapped in suction lines (also possible with flooded suction due to uneven 

rise in piping; eliminate humps and hollows).

  4.  No water at source or water level too low.

  5.  Valve on suction lines closed. Open valve & pump will restart automatically 

or press “Prime” button.

b)  PUMP SWITCHES ON AND OFF FREQUENTLY (CYCLING)

c)  MOTOR DOESN’T START WHEN SWITCHED ON - INDICATOR LIGHTS NOT 

ILLUMINATED

WARNING: Automatic reset thermal overloads may allow the pump to restart 

without warning. Always disconnect the pump motor from the electrical 

supply before maintenance or repairs.

WARNING: When servicing or attending pump and/or controllers, always 

ensure power is switched off and lead unplugged. Electrical connections 

should be serviced only by qualified persons.

d)  MOTOR STOPS - YELLOW STATUS INDICATOR LIGHT IS ILLUMINATED.

  1.  Motor ”over temperature” cut-out tripped. Consult Davey dealer.

  2.  Motor not free to turn - e.g. a jammed impeller. Consult Davey dealer.

  3.  Prime button has been held in for too long. Release prime button and switch 

off power for 1 minute to allow unit to reset.

  4.  Your Torrium2 has detected high water temperature in the pump. Once the 

water has cooled the Torrium2 will automatically restart the pump.

e)  PUMP WILL NOT STOP

  1.  Water leaks on discharge side of pump.

f)  PUMP WILL OPERATE NORMALLY INITIALLY BUT WILL NOT RESTART 

ON WATER DEMAND - STATUS INDICATOR LIGHT NOT ILLUMINATED

  1.  Power supply problem - see c) 1.

g)  PUMP WILL OPERATE NORMALLY INITIALLY BUT WILL NOT RESTART ON 

WATER DEMAND - YELLOW STATUS INDICATOR LIGHT IS ILLUMINATED.

  1.  Suction air leak - pump has partially lost prime.

  2.  Blocked impellers or suction.

  3.  Discharge valve closed - open valve.

Maintenance

The only regular attention your new pressure system may require will be if you 

have used an additional pressure tank. Depending on the tank used you may need 

to check the pressure tank’s air charge every 6 months. Follow the instructions 

applicable to each tank.

WARNING : Under no circumstances should Torrium2 controller be 

disassembled. Failure to observe this warning will expose persons to the 

possibility of personal injury and may also result in damage to other property. 

Do not dismantle, no user serviceable parts, spring under pressure.

Summary of Contents for BT14-300

Page 1: ...pework be disassembled unless the internal pressure of the unit has been relieved Failure to observe this warning will expose persons to the possibility of personal injury and may also result in damage to the pump pipework or other property WARNING Failure to follow these instructions and comply with all applicable codes may cause serious bodily injury and or property damage NOTE Prior to installa...

Page 2: ...tc 2 Provides automatic cut out protection should the pump run out of water or overheat should the pump fail to start due to low voltage or a blockage in the pump 3 Provides an easy to understand visual representation of the system status 4 Has adaptive pressure cut in which allows the pump to start at approximately 80 of the maximum pressure at last shut down This allows the controller to accommo...

Page 3: ...he controller adaptor nut is able to rotate independent of the Torrium2 and the complete pump this allows it to be tightened onto the pump easily For ease of installation a tightening tool is included with Torrium2 to tighten the controller nut to ensure a firm connection to your controller The ability to rotate the adaptor nut also means that the complete controller once fitted to the pump can be...

Page 4: ... be horizontally mounted on a firm base allowing for drainage to avoid damage to flooring etc that over time may occur from leaking pipe joints or pump seals Do not mount the pump vertically Never place flammable materials on or near your pump WARNING Some insects such as small ants find electrical devices attractive for various reasons If your pump enclosure is susceptible to insect infestation y...

Page 5: ...lightning or a very powerful surge hits the pump unit If the installation is subject to electrical power surges or lightning we strongly recommend the use of suitable additional surge protection devices on ALL electrical equipment Always disconnect and lockout all electrical power when installing or working on pumps motor or switches Insure the power supply breaker is off or the disconnect where u...

Page 6: ...ons For best performance use P V C or polythene pipes at least the same diameter as the pump s inlet and delivery outlet openings Larger diameter pipe may be used to minimise resistance to flow when pumping longer distances NOTE For protection the Davey pump motors are fitted with an automatic reset thermal overload constant tripping of this overload indicates a problem e g low voltage at pump exc...

Page 7: ...some suction lift installations there may be good reason to modify the inbuilt check valve to ensure that the discharge pressure is also applied to the suction line and footvalve This could be where the suction line was very long or where there was concern regarding a leaking footvalve This may not always be applicable and it is acceptable to retain the inbuilt check valve in the Torrium2 on sucti...

Page 8: ...lations 8 Models Maximum Inlet Pressure BT14 300 60 psi BT30 30 BT20 30 50 psi BT14 45 40 psi BT20 40 20 psi NOTE The above pressure limits also apply to well pump boosting Connection to your Water Source FLOODED SUCTION FROM CISTERN OR STORAGE TANK Installations with flooded suction require a gate valve so water supply can be turned off for pump removal and servicing FLOODED SUCTION FROM MUNICIPA...

Page 9: ... home pressures and in those cases the pressure reducing valve will need to be set to lower pressures Note The maximum System Pressure should not exceed 100psi Local code limits for home pressure Pressure reducing valve setting psi BT14 30 BT20 30 BT14 45 BT20 40 BT30 30 No limit 60psi 50psi 40psi 20psi 50psi 80psi 40psi 30psi 30psi N A 30psi 70psi 30psi 20psi 20psi N A 20psi The chart above shows...

Page 10: ... water demand Priming and Operation The Torrium2 module fitted to your BT Booster is provided with a push button Prime button This button is used during initial priming of the pump and also acts as a reset button if the Torrium2 switches out in pump protection mode 1 Remove priming plug and fill casing and suction line on flooded suction or mains boosting simply open gate valve to pump When full r...

Page 11: ...Consult Davey dealer 2 Motor not free to turn e g a jammed impeller Consult Davey dealer 3 Prime button has been held in for too long Release prime button and switch off power for 1 minute to allow unit to reset 4 Your Torrium2 has detected high water temperature in the pump Once the water has cooled the Torrium2 will automatically restart the pump e PUMP WILL NOT STOP 1 Water leaks on discharge s...

Page 12: ...ring servicing use only approved non petrochemical based oring and gasket lubrication If unsure consult your Davey Dealer for advice WARNING Do not use hydrocarbon based or hydrocarbon propelled sprays around the electrical components of this pump This pump is not to be used by children or infirm persons and must not be used as a toy by children WARNING When servicing or attending pump always ensu...

Page 13: ...NOTES 13 ...

Page 14: ...13 NOTES ...

Page 15: ... Customer Service line on 1300 367 866 in Australia or 0800 654 333 in New Zealand send a written letter to Davey at the address listed above or email sales davey com au 2 Any warranty claim must be accompanied by proof of purchase and details of the alleged defect 3 On receipt of your claim Davey will seek to resolve your difficulties or if the product is faulty or defective advise you on how to ...

Page 16: ...eyusa com AUSTRALIA Head Office 6 Lakeview Drive Scoresby Australia 3179 Ph 613 9730 9124 Fax 613 9753 4248 Email export davey com au Website davey com au NEW ZEALAND 7 Rockridge Avenue Penrose Auckland 1061 Ph 0800 654 333 Fax 0800 654 334 Email sales dwp co nz Website daveynz co nz EUROPE ZAC des Gaulnes 355 Avenue Henri Schneider 69330 Meyzieu France Ph 33 0 4 72 13 95 07 Fax 33 0 4 72 33 64 57 ...