3
OPERATING MANUAL
ABOUT YOUR OPTICAL LEVEL
Thank you for purchasing this DATUM OPTICAL LEVEL. Your measuring tool features 32x
magnification, a peep sight and a bubble level mirror for ease of use.
Please read and understand the content of this instruction manual before using this product.
Save this manual for future reference.
SPECIFICATIONS
MODEL
DL32X
ACCURACY
±1mm at 1km double run levelling
LEVELLING ACCURACY
±3°
SETTING ACCURACY
±0.3”
COMPENSATOR
Air-damping compensation system
COMPENSATOR WORKING RANGE
±15’
HORIZONTAL CIRCLE PROTECTOR
360°
MAGNIFICATION
32X
FIELD OF VIEW
1°20’
MINIMUM SIGHTING DISTANCE
40cm
STADIA MULTIPLICATION
100
EFFECTIVE APERTURE LENSE SIZE
36mm
TRIPOD THREAD
5/8”
IP RATING
IP54
DATUM is constantly improving its products. All information in this manual is based on the latest product information available at the time of
printing. The specifications outlined herein are subject to change without prior notice or obligation.
HAZARD SIGNAL WORD DEFINITIONS
!
Indicates an imminently hazardous situation which, if not avoided, will result
in death or serious injury. Obey all safety messages that follow this symbol to
avoid possible injury or death.
DANGER
Indicates an imminently hazardous situation which, if not avoided, will result
in death or serious injury.
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result
in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result
in minor or moderate injury.
CAUTION
Used without the safety alert symbol indicates a potentially hazardous
situation which, if not avoided, may result in property damage.
!
!
!