![Dateq SPL6 Manual Download Page 21](http://html.mh-extra.com/html/dateq/spl6/spl6_manual_513790021.webp)
UK
DATEQ SPL6 configuration manual
Configuration
21
Limiter configuration
The manual configuration of sound level parameters.
Mode
•
Live Limiter and recorder
•
Line Limiter and recorder
In Live mode the limiter will reduce the output level on microphone
measurement. The microphone actively influences the output level.
In Line mode the limiter only acts on the line level input. The microphone is
used for audio level recording only.
Limiter settings
Maximum dBA: 50dB tot 125dB.
Maximum dBC: 50dB tot 125dB.
Maximum peak: 50dB tot 125dB.
Input threshold: -50dB tot +18dB.
Output attenuation: -60dB tot 0dB.
Maximum reduction: 60dB tot 0dB.
Certification date
The certification date is set to enable future inspection. Till the certification date the limiter will
function as normal. On passing the selected date the limiter will reduce the output signal with an
extra 18dB and display the 'certification invalid' message on the front panel display.
The limiter can only be unlocked and reset by a certified installer.
Microphone settings
Microphone correction: -30dB till +12dB.
Microphone distance: 0 till 30 meter.
Sanction settings
Time till sanction: 10 tot 360 seconds.
Sanction time: 10 tot 360 seconds.
As soon as overload will become active, the sanction timer will start running.
When overload becomes inactive, the sanction timer will decrees each counted second.
Note; Changes are effective immediately.
Summary of Contents for SPL6
Page 2: ...SPL5_040825_V1 0EN ...
Page 12: ......
Page 13: ...SPL6 Multiband limiter Sound level recorder Configuration ...
Page 14: ...Notes ...
Page 32: ...32 Configuration DATEQ SPL6 Configuration manual UK ...