background image

13 

 

MusiCall installation manual 

UK 

 

V14360903 

The default values for each output can be independently set. 
Volume,  EQ  and  balance.  These  values  will  be  set  during 
after  a  power  cycle.  Balance  is  only  available  for  stereo 
selected  zones.  The  EQ  settings  have  a  range  of  +  and  -
12dB. The volume setting has a range of 50 steps within the 
set minimum and maximum range. 
 
 
 

 

The main paging volume for each output can be set. This volume setting is set 
global  for  all  paging  calls  including  priority  audio.  Selecting  whether  or  not  to 
page the independent zones can be set in the paging tab. See page 15 in the 
manual.  
 
 
 
 

 

By  selecting  Muted  the  output  will  default  be  set to mute. When 
pressing  ‘volume  +’  or  ‘volume  –‘  the  output  will  return  to  it’s 

default set volume. 
 

Summary of Contents for Musicall MAX8.16

Page 1: ...V14360903 MAX 8 8 MAX8 8D MAX8 16 MAX8 16D MusiCall Installation manual ...

Page 2: ...UK MusiCall installation manual 1 V14360903 Notes ...

Page 3: ... equipment may only be connected to a legally approved earthened mains power supply 11 The power cable or power cord must be positioned such that it cannot be walked on in normal use and objects which might damage the cable or cord cannot be placed on it or against it Special attention must be paid to the point at which the cable is attached to the equipment and where the cable is connected to the...

Page 4: ...equipped with a quadruple DAB FM and WEB tuner Model with 8 stereo mono zones 3 stereo 6 mono RCA inputs and optional 8 local audio inputs Each can be equipped with it s own MRC wall controller and MRA local audio input Configuration and control possible using the internal webserver Musicall MAX8 8D The MAX8 16 is the standard central matrix Model with 8 stereo 16mono zones 8 stereo 16 mono RCA in...

Page 5: ... audio input Three inputs can be used to activate room combining One input can be used to activate the priority audio input The last input can be used to connect an external system mute for fire alert and evacuation purposes The telephone audio input can be configured to auto answer or audio detect Logic IO Using the logic IO paging can be remotely activated The logic output scan be configured to ...

Page 6: ...plifier manual Devices using ballanced inputs Devices using ballanced audio input scan be connected using a converter cable These cables can be made using the following schematic Antenna To be able to use the internal tuners on the MAX8 8D and MAX8 16D an antenna needs to be connected This antenna can be a CAI Central Antenna Installation or external outdoor antenna For the use of DAB check your C...

Page 7: ...tem When not connected in the right way no audio will be fed through The MRA1 is equipped with an internal gain trimmer to adjust input sensitivity To avoid distortion the local audio inputs must be connected using shielded cable Best is to use standard shielded microphone cable The cable shield can be connected to the ground on the local audio input If needed the shield can also be connected to t...

Page 8: ...n be connected to the Audio Pots input When using a logic trigger remote input 4 must be connected By shorting remote input 4 the audio input becomes active The audio input can also be activated by audio detections How to configure this can be found in the configuration chapter System mute Remote input 5 can be connected to act as system mute for emergency use The input can be set to normal open o...

Page 9: ...t the wallunit is 15Vdc it is very likely that the cable is connected to the outermost pins at the matrix side These two pins are to be used by the MRA instead When I select the local input and adjust the volume I can hear a high pitch buzzing sound When the MRA and wallunit cable are in parallel they will interfere with each other It is recommended to use a shielded cable for the MRA and a separa...

Page 10: ...cted directly to a computer both normal and cross patch cables can be used When directly connected to the matrix an IP address must be manually assigned to the computer The MAX matrix can be configured using http musicall config html It can also be reached using http matrix IP address config html If the IP address of the matrix is unknown the matrix can be found using the Musicall_lookup program T...

Page 11: ... affected by this restore Select the desired function or functions and click do restore When connected to the internet the MAX matrix will automatically use the NTP internet time Select the desired timezone to adjust DST can be enabled where needed If no internet access is available the MAX8 8D and 8 16D can also link to the local RDS time When connected to the internet the MAX systems can downloa...

Page 12: ...MAX8 8D and MAX8 16D the first five auxiliary inputs are used for tuner 1 4 and the web encoder aux 5 The auxiliary inputs now function as direct outputs from the tuners and encoder Each input can be assigned to be used global trough out the matrix or can be assigned to a specific zone When assigned to a specific zone the input is not available to other zones On page 14 the scroll list is explaine...

Page 13: ...g to rear of the matrix The MAX8 8 and MAX8 8D have the MIX option When selecting MIX the output becomes dual mono The MAX8 16 and MAX8 16D have the ST option With this 8 stereo up to 16 mono zones can be selected For each output a default source can be selected From boot up the output will start using the assigned source The available list corresponds with the assigned source list A volume range ...

Page 14: ... 12dB The volume setting has a range of 50 steps within the set minimum and maximum range The main paging volume for each output can be set This volume setting is set global for all paging calls including priority audio Selecting whether or not to page the independent zones can be set in the paging tab See page 15 in the manual By selecting Muted the output will default be set to mute When pressin...

Page 15: ...cting or drag and drop Removing a single source is done in the same way as adding them Select the source that needs to be removed and click on move Drag and drop also works When a tuner is fixed to an output it is possible to add frequency presets to a sourcelist Then a tuner is selected as public source the tuner works on a single frequency This frequency can be changed in the configuration webse...

Page 16: ...he paging option includes a play out of a recorded file like a ding dong This short audio file will be played after closing the GPI contact After the file has finished playing the paging microphone will be switched to all selected outputs Paging chimes are stored onto the internal storage of the matrix Supported audio formats are mp3 wav en flac To enable the chime play out select the desired file...

Page 17: ...ferent wallunit texts can be changed These texts are valid for all zones RDS information RDS information can be displayed on the wallunit when a tuner is selected By default it is deselected and the tuner name or preset will be visible EQ setting When this checkbox is enabled it allows users to change the EQ settings for their zone By pressing channel and volume the user enters the settings menu C...

Page 18: ...roomcombining groups 1 2 and 3 Configuring them can be found in the next chapter on page 18 Priority audio Priority audio can be connected to the Audio Pots input When using a logic trigger remote input 4 must be connected By shorting remote input 4 the audio input becomes active The audio input can also be activated by audio detection On detecting an audio signal like commercial playout or alarm ...

Page 19: ...r multiple rooms By default users can only reach the matrix connected within the LAN By checking the Access WAN checkbox the matrix allows external control through a VPN or public connection Internet Click Change to add or change a user The added user is immediately active and can access the matrix When users are added the configuration pages can only be reached by added users using a username and...

Page 20: ...pre defined PI list This PI list allows to automatically add the stations name to the preset list This name will be visible within the scroll list and user display It is also possible to adapt the preset name This adapted name will also be used within the scroll list and user display Like all in and outputs the name can contain 12 characters maximum Besides the automatic search presets can be manu...

Page 21: ...an be set to either FM or DAB By default all tuners are set to FM For use of DAB reception each tuner can independently be set to DAB After changing FM to DAB the DAB preset list is automatically loaded containing al available DAB channels Note it can take up to 30 seconds before all stations are loaded depending on signal strength The tuner will automatically add names to the DAB stations These n...

Page 22: ...Within the URL field the source of the stream can be added or changed Supported stream formats MP3 WAV FLAC All formats are supported on 44 1KHz mono or stereo Press play to start the stream Note this can take some seconds When the Web tuner is fixed to an output it is possible to add webstream presets to a sourcelist Then the Web tuner is selected as public source the encoder works on a single we...

Page 23: ...call config html Where needed the DHCP client can be deactivated and a static address can be entered In a network that holds more than one MAC808 or Musicall system each system will be displayed in the IP tab To access these systems click open and the internal webserver will be accessed DHCP protocol to supply IP addresses DHCP offers an automatic network configuration DNS Resolves an IP address f...

Page 24: ...Output volume adjustment 12 60 dB THD N 0 08 CCIR RMS 0dBu FREQUENCY RESPONCE Input to output 25 Hz 20 kHz 1 dB WALLUNIT CONNECTION Output voltage 24V Maximum output current 20mA automatic fuse CONSOLE CONNECTORS Output voltage 24V Maximum output current 200mA automatic fuse COMMUNICATION Baudrate RS232 14kbps USB USB2 Ethernet 10 100MBit auto select GENERAL Mains supply Input voltage 110 230 VAC ...

Page 25: ...steuning Voor vragen over het Musicall systeem accessoires en andere producten kunt u contact opnemen met Dateq Audio Technologies B V De Paal 37 Telefoon 036 54 72 222 1351 JG Almere Fax 036 53 17 776 Nederland E mail info musicall nl Internet www musicall nl ...

Reviews: