EN
DATEQ BCS50 user manual
BCS58 master
33
Jumper settings
With two jumpers the AutoPFL function can be configured. The jumpers are situated on a small
add-on PCB at the left PCB of the BCS50 master unit.
By default the mixer is configured to disable the AutoPFL function when the C.R. selector is
switched to audition. In all the other cases the C.R. selector will automatically switch to PGM or
AIR when the DJ-microphone is activated. It is also possible to disable this function when AUX is
selected or to disable all AutoPFL functionality. See the table below:
Jumper settings
Description
J1J5
J2DIS
J3AUD
J4AUX
Default
Default setting. No AUTO-PFL when AUD is
selected on the C.R. selector.
J1J5
J2DIS
J3AUD
J4AUX
Always active
AUTO-PFL always active.
J1J5
J2DIS
J3AUD
J4AUX
No AUTO-PFL
AUTO-PFL disabled.
J1J5
J2DIS
J3AUD
J4AUX
AUX
No AUTO-PFL when AUX is selected on the C.R.
selector.
J1J5
J2DIS
J3AUD
J4AUX
AUD+AUX
No AUTO-PFL when AUD or AUX is selected on
the C.R. selector.