background image

Summary of Contents for RMC-180

Page 1: ......

Page 2: ...d Services The information offered in this instruction manual is intended as a guide only At all times Datavideo Technologies will try to give correct complete and suitable information However Datavideo Technologies cannot exclude that some information in this manual from time to time may not be correct or may be incomplete This manual may contain typing errors omissions or incorrect information D...

Page 3: ...that the total of the ampere ratings on the products plugged into the extension cord do not exceed the extension cord rating 10 Make sure that the total amperes of all the units that are plugged into a single wall outlet do not exceed 15 amperes 11 Never push objects of any kind into this unit through the cabinet ventilation slots as they may touch dangerous voltage points or short out parts that ...

Page 4: ... extension to the standard Warranty providing the product is registered with Datavideo within 30 days of purchase For information on how to register please visit www datavideo com or contact your local Datavideo office or authorized Distributors Certain parts with limited lifetime expectancy such as LCD Panels DVD Drives Hard Drives are only covered for the first 10 000 hours or 1 year whichever c...

Page 5: ...Focus Gain and other functions over Ethernet Multiple presets for PTZ settings for each individual camera Full remote control of each camera via serial communication over affordable network cabling Compatible with Datavideo s switcher tally indicators Compact design for easy installation Easy integration with Datavideo HD switchers for an affordable multi camera solution 1 2 Compatible Control Sta...

Page 6: ...se dials Push to select a specific item and rotate to browse the menu FOCUS To manually control the FOCUS setting first press the AUTO MANUAL button so the button LED is turned ON The FOCUS dial can then be rotated to set the focus If the AUTO MANUAL button is disabled OFF the camera will be in AUTO FOCUS mode Mode Select MODE The selected PTC 150 camera will output colour bars Press again to retu...

Page 7: ...ese buttons The selected channel button will be turned ON LOCK Button When enabled the joystick will be in the lock state To resume its functional status simply press the button once to unlock the joystick PTZ Joystick Control Note Before attempting to use the joystick to PAN TILT or ZOOM a selected camera first make sure the LOCK button is not enabled If the LOCK button LED is ON the joystick is ...

Page 8: ...sponds to one stored camera position The activated button LED will be turned ON Tally Indicator LEDs Each set of the four memory buttons is assigned a Tally Indicator LED This LED feature becomes active when the RMC 180 is connected to the tally output of a compatible Datavideo Switcher such as the HS 2000 or HS 2200 When the HS 2000 or HS 2200 Switcher is sending camera A s video to the program o...

Page 9: ... as the HS 2000 or HS 2200 Upon receiving the video switcher s tally output signals the corresponding Tally LED indicator on the RMC 180 keyboard will be turned ON giving the operator an indication of which camera is currently live at the switcher end DC In Socket Connect the supplied 12V 0 5A PSU to this socket The connection can be secured by screwing the outer fastening ring of the DC In plug t...

Page 10: ...te to browse the menu FN1 Exit FN2 USB HID MODE USB HID vX X FN3 CAM ADDR ADDR 81 82 83 84 85 86 87 FN4 JOYSTICK DIR Pan NORMAL REVERSE Tilt NORMAL REVERSE ERROR FN5 VIDEO FORMAT 1080 60i 1080 50i 720 60p 720 50p 1080 30p 1080 25p 1080 60p 1080 50p FN6 POWER ON EXECUTE OFF FN7 SCREEN MODE MIRROR H V H V OFF FN8 MEMORY SPEED SPD 1 18 FN9 TALLY LED MODE TALLY USER TALLY OFF TALLY RED TALLY GREEN TAL...

Page 11: ... The camera address setting must match the VISCA ID setting of the PTC 150 DIP switch which can be located at the bottom of the PTC 150 camera For example VISCA ID 1 corresponds to the camera address 81 FN4 JOYSTICK DIR FN4 sets the PAN and TILT directions PAN toggles the camera pan direction between NORMAL and REVERSE TILT toggles the camera tilt direction between NORMAL and REVERSE Note When ERR...

Page 12: ...ght In this mode the user can toggle between Tally Off Tally Red and Tally Green The Tally Input mode is selected when the RMC 180 is connected to the tally output of a compatible Datavideo Switcher such as the HS 2000 or HS 2200 FN10 R B Gain Adj FN10 allows the user to manually adjust the white balance setting However before you use this function please make sure Button B is enabled Button LED O...

Page 13: ...position 1 Select a camera first CH A CH B CH C CH D 2 Adjust the camera lens to the desired position or view using the joystick Also set the focus iris and zoom of the selected camera 3 Push the STR STORE button and it will turn red 4 As soon as the corresponding four memory buttons of the selected camera channel start flashing simply select and press a memory button to save the current PTZ setti...

Page 14: ...PIN Assignment D Sub 15 PIN Female The PIN assignment of the Tally Input Connector is shown in the following table Channel CH 1 CH 2 CH 3 CH 4 PGM Tally PIN 1 PIN 6 PIN 11 PIN 5 PVW Tally PIN 3 PIN 8 PIN 13 PIN 15 GND PIN 4 9 14 ...

Page 15: ...plete Once started the update process should not be interrupted in any way as this could result in a non responsive unit Requirement Latest firmware update files bootloader and application firmware A USB A to USB A cable not longer than 2 meters A Windows PC with USB 2 0 ports 1 Power off the RMC 180 and connect the USB A cable between the USB firmware upgrade port on the RMC 180 rear panel and a ...

Page 16: ...shown below 6 Double click on the RMC 180_U38 removable storage device and delete the bootcode bin file 7 Copy and paste the latest firmware file bootcode bin into the RMC 180_U38 removable storage device 8 Reboot the RMC 180 device until the LCD displays the following 9 Press the MENU key to start the firmware upgrade and do not disconnect the power before the upgrade is complete ...

Page 17: ...roceed to upgrading the application firmware 11 Remove bootcode bin from the RMC 180 device and copy and paste the application firmware into the RMC 180 device 12 Reboot the RMC 180 device again and the LCD display will now show the following 13 The RMC 180 device is now ready for controlling the connected cameras ...

Page 18: ...18 7 Dimensions ...

Page 19: ...19 Service and Support ...

Reviews: