14
See below for information about RJ-45 cabling (RS-422 wiring scheme between RMC-180 and PTR-
10) in the RS-422 setup environment.
RMC-180 (RJ-45 Port)
PTR-10 (RS-422 IN)
GND
1
White/Orange
White/Orange
1
GND
NC
2
Orange
Orange
2
NC
TX-
3
White/Green
White/Green
3
RX-
RX-
4
Blue
Blue
4
TX-
RX+
5
White/Blue
White/Blue
5
TX+
TX+
6
Green
Green
6
RX+
NC
7
White/Brown
White/Brown
7
NC
NC
8
Brown
Brown
8
NC
DVIP (RMC-300C)
To control multiple PTR series devices with the RMC-300C, you will first have to connect them to the
same network via DVIP port. The RMC-300C allows you to control up to 24 PTR series devices
simultaneously. See the diagram below for an example system connection setup in a DHCP / LAN
network and also refer to the RMC-300C user manual for instructions.
PTR series device usually has a default static IP address of 192.168.100.XXX. Using an RJ-45 Ethernet
cable, the unit can be directly connected to a Windows-based computer assigned of an IP address
with the same first three octets as the unit’s default IP address. The following setup procedure
outlined below should allow you to initially configure the unit before moving it to an existing DHCP /
LAN network.
GND