13
4. RS-232/RS-422 Pinout
You can use RS-232 or RS-422 control protocol to control the PTR-10T
MARK II behind the HBT-12 HDBaseT Receiver Box with Datavideo
camera controllers such as RMC-180, RMC-300A or RMC-300C. You will
need to use a custom Ethernet cable to connect between the controller
and HBT-12. Wire the connection cable according to the respective RS-
232 and RS-422 wiring diagrams shown below.
RS-232
Remote Controller
HBT-12 Receiver Box
GND
1
White/Orange
White/Orange
1
GND
NC
2
Orange
Orange
2
NC
NC
3
White/Green
White/Green
3
TX-
NC
4
Blue
Blue
4
RX-
RXD
5
White/Blue
White/Blue
5
RX+
TXD
6
Green
Green
6
TX+
NC
7
White/Brown
White/Brown
7
NC
NC
8
Brown
Brown
8
NC
Remote OUT
RS-232/RS-422 Port
GND