D T - 6 X X X BiSync to Async ASCII Printer Application U s e r ' s M a n u a l
B u i l d 9 . 0
04/18/06
Datatek Applications Inc.
11
1 DT-6XXX <--> UMI B2APRT
2.3.2 SYNC8
C
ONFIGURATION
The following console output reflects the output of the SYNC8
verify
command. The results
displayed below describe a bsc3270 configuration consistent with the configuration needs of the
previous network diagram. For a more detailed description of how to configure the SYNC8
Module, refer to the
BNS-2000 SYNC8 Module Reference Guide
.
Note: knowledge of the BiSync Host's configuration is required to properly configure the BNS
SYNC8 module
CC0> vfy bsc terminal 30 2 2 4
MODULE ADDRESS:
30
MODULE TYPE:
bsc3270
NCHLS:
100
SERVICE STATE:
in
DOWNLOAD SERVER:
controller
VERSION:
standard
HOST MSG CODE PORT BAUD
PORT CHNLS TYPE TYPE CHNG SET DUPLEX RATE SRVC
2 7 host vtam no ebcdic full 9600 in
PORT COMMENT
2 to bsc printer
PORT CU SRVC
2 2 in
TERM SCRN RECV LOGOFF LOGOFF FWD
PORT CU TERM TYPE SIZE GRP METHOD SEQ ID ACK SRVC
2 2 4 basic/ro N/A bscprt none N/A N/A in
BKPL
PORT CU TERM CHNL
2 2 4 16
2.3.3 DT-6XXX
P
LATFORM AND
IP-B2APRT A
PPLICATION
C
ONFIGURATION
The DT-6XXX software is composed of two components. One component, called the
Platform,
exists to support all applications. The second component is comprised of the individual
application
(s)
.
The
Platform
provides Operating System functions, selected interfaces, protocol stacks, SNMP
functions, and system OA&M while each
application
uses the services of the resident
Platform
.
2.3.3.1 DT-6XXX
P
LATFORM
C
ONFIGURATION
The following console output reflects the output of the DT-6XXX
vfymod
and
vfycfg
commands.
The results displayed below describe a DT-6XXX platform configuration consistent with the
configuration needs of the previous network diagram. For a more detailed description of how to
configure the DT-6XXX platform, refer to the
DT-6XXX User's Manual
.