background image

4209-00009-000   EasyRead (DSV3-EP) User’s Manual 

Rev 0E 

 

6/29/2009 

Copyright © 2009 by Datastrip, Inc.  All rights reserved.   

Reproduction in whole or in part is prohibited. 

  

External Power 

Connected? 

Battery 

Charge State 

Power Status 

LED Color 

Power Status LED Blink Rate 

 

 

 

 

 

System Powered OFF 

 

 

 

Yes 

No Battery 

Green 

Very Slow Blink 

 

Yes 

Charging 

Green / Red 

Continuous with Slow Color Blink 

 

Yes 

Fully Charged 

Green 

Very Slow 

 

 

 

 

 

WinCE Running 

 

 

 

No 

OK / Not Low 

Green 

Slow Blink 

 

No 

Low 

Red / Green 

Continuous with Color Toggle 

 

Yes 

No Battery 

Green 

Solid 

 

Yes 

Charging 

Green / Red 

Continuous with Color Blink 

 

Yes 

Fully Charged 

Green 

Solid 

 

 

 

 

 

System In Suspend Mode

 

 

 

 

 

No 

OK / Not Low 

Yellow 

Slow Blink 

 

No 

Low 

Red / Yellow 

Continuous with Color Toggle 

 

Yes 

No Battery 

Yellow 

Solid 

 

Yes 

Charging 

Yellow / Red 

Continuous with Color Blink 

 

Yes 

Fully Charged 

Yellow 

Solid 

 

Definitions 

 

Solid

:  LED is ON continuously. 

 

Slow Blink

:  LED is ON 50% of the time, blinking every 2.5 seconds (50% duty cycle, 2.5 sec period). 

 

Very Slow Blink

:  Mostly dark with quick blink approx every 5 seconds (~1% duty cycle, 5 sec period). 

 

Continuous with Slow Color Blink

:  LED is ON continuously with a 5 sec period, where color 1 is ON for 4.9 sec 

and color 2 is ON for 0.1 sec. 

 

Continuous with Color Blink

:  LED is ON continuously, with a 2.5 sec period, where color 1 is ON 2 sec, and 

color 2 is ON 0.5 sec. 

 

Continuous with Color Toggle

:  LED is ON continuously, alternating evenly between the two colors (50% Duty 

Cycle, 2.5 sec Period). 

4.4

 

Battery Charging and Replacement 

The terminal uses one 5000 mAH Lithium Polymer battery pack.  Under normal operating conditions, the 
battery does not need to be removed.  The terminal has an internal charging circuit that will charge the 
battery whenever the unit is connected to the external AC power adapter.   

If the user does want to replace the battery, it may be replaced when the unit is off, or the battery may be 
hot swapped when the unit is in Suspend mode.  To hot swap the battery, save any work in progress and 
put the unit into Suspend by tapping the power button (or via the Suspend command on the Start Menu).  
Turn the quick release (quarter-turn) bails on the battery access cover on the rear of the unit.  Remove the 
old battery and replace it with a charged battery within 30 seconds to prevent the unit from shutting down.  
Replace the battery-access cover and re-fasten it by tightening the quick release bails. 

 

Quick Release 

Receptacles 

Quick Release 

Bails 

Quick Release 

Receptacles 

Quick Release 

Bails 

EasyRead (DSV3-EP) 

EasyVerify (DSV3-SP) 

Summary of Contents for DSV3-EP

Page 1: ...Lead Software Engineer Reviewer __________________________________________________ Date ___________ Scott Robinson Hardware Manager Reviewer __________________________________________________ Date ___...

Page 2: ...4209 00009 000 EasyRead DSV3 EP User s Manual Rev 0E 6 29 2009 1 Copyright 2009 by Datastrip Inc All rights reserved Reproduction in whole or in part is prohibited EasyRead DSV3 EP User sManual...

Page 3: ...d stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording scanning or otherwise except as permitted under section 107 or 108 of the 1976 Un...

Page 4: ...4 10 1 USB Ports 12 4 10 2 Compact Flash CFIO Slot 12 4 10 3 Secure Digital Memory Card SDIO Slot 12 4 10 4 Audio Headset Jack 13 4 11 CONTACTLESS SMART CARD READER 13 4 12 OPTIONAL PERIPHERAL MODULE...

Page 5: ...nstructions 27 10 6 EPASSPORT ICAO VIEWER ICAO VIEWER EXE 27 10 6 1 EPassport Overview 27 10 6 2 ePassport Security Mechanisms 28 10 6 3 ICAO Viewer Operation 28 11 ACTIVE SYNC 30 11 1 ACTIVESYNC VIA...

Page 6: ...FIS quality Automated Fingerprint Identification System biometric matching algorithms and rugged biometric sensors All of the DSV3 family of mobile terminals are rugged and environmentally sealed unit...

Page 7: ...ocumentation User Manual on CD End User License Agreement and Quick Start Guide Please retain the shipping box in the event you need to return your product for service 3 Initial Setup Each unit is shi...

Page 8: ...l indicate that the system is booting During this time the BIOS is loaded and diagnostic testing is performed When the unit finishes powering up the Windows CE NET desktop will appear on the display 4...

Page 9: ...rminal is goes into Suspend mode None Button released 1 x 15 sec The terminal is powered OFF normally Falling Tone Button released x 15 sec The terminal performs an emergency shutdown Warning Tone Win...

Page 10: ...s ON for 4 9 sec and color 2 is ON for 0 1 sec Continuous with Color Blink LED is ON continuously with a 2 5 sec period where color 1 is ON 2 sec and color 2 is ON 0 5 sec Continuous with Color Toggle...

Page 11: ...powers the Real Time Clock for more than 6 months while the unit is off This battery is automatically recharged by the system and does not require any operator service CAUTION Use ONLY approved replac...

Page 12: ...matching algorithms from a variety of the industry leading vendors such as Identix Cogent Bioscrypt Motorola and NEC However the Identix algorithm is the only algorithm directly available from Datast...

Page 13: ...ack 4 10 1 USB Ports There is one USB Host port and one USB client port on the mobile terminal that are accessible under the rubber I O port cover These are USB 2 0 High Speed 480 Mbps ports however t...

Page 14: ...rt ISO 14443 smart card media Either antenna can be used to read these smart card media however the upper antenna is typically more convenient Place and hold the media to be read against the back of t...

Page 15: ...to suit your personnel preferences the following options are available Calibration If your device is not responding properly to your screen taps you may need to recalibrate your screen Go to the Contr...

Page 16: ...ake up the unit to a fully on condition Suspend This state is entered when no major background software tasks are running and the touch screen or function keys have not been used for some user configu...

Page 17: ...Very Low This warning will repeat itself periodically until the condition clears or the unit automatically shuts down An error beep sounds when the battery charge level is critical 5 5 Creating Deskt...

Page 18: ...inal type DSVII SC DSVII SW DSVII PA DSV3 SP or DSV3 EP and writes the appropriate platform type information into the registry along with the other registration information 6 3 DsVerify Registry Saver...

Page 19: ...rint sensor Once complete a green window with a number 1 should appear to indicate the sensor was successfully calibrated Double tap the DsVerifyFpCaptureTest application Look in the lower right hand...

Page 20: ...dating the smartcard firmware is as follows In the directory My Device Hard Disk DSV3 folder run the utility DsVerifyCleanUp and select the option Clear SCM Firmware Answer OK to the question Are you...

Page 21: ...rs the reason for the failure is provided With all updates with the exception of the Embedded Controller the user is then placed back to the main screen of the app 4 update buttons The user may then u...

Page 22: ...ification ISO 14443 A B Operating Frequency 13 56 MHz Optical Scanner Scan Area 124 W x 42 H mm 4 88 W x 1 65 H in Standard Symbologies OCR OCR B 2D Codes PDF417 1D Codes Code 39 Code 93 Code 128 UPC...

Page 23: ...ions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interferenc...

Page 24: ...was stored on the document the application will also perform a one to one match of a fingerprint stored on the document to the fingerprint captured by the on board fingerprint sensor This demonstrates...

Page 25: ...he fingerprints Typical threshold values are Cogent 1000 Identix Low 200 High Not used Clicking on the OK will save the settings and return the application to the Configuration screen Clicking on the...

Page 26: ...d the settings are stored in the registry and restored the next time the application is run The Digital Still Camera settings include Setting Selections Available Description of Setting Brightness 2 0...

Page 27: ...bed above and an automatic scanning mode that will retrigger again after a successful read was completed The operator can choose between different illumination sources by using the radio button at the...

Page 28: ...key will toggle between manual scanning mode as described above and automatic scanning mode that will retrigger again after a successful read was completed 10 6 EPassport ICAO Viewer ICAO Viewer exe T...

Page 29: ...until the machine readable zone is read first 10 6 3 ICAO Viewer Operation After opening the application follow the instructions in the dialog box at the bottom of the main screen and wait for the Sc...

Page 30: ...cessful PA red PA failed PA orange PA not performed Audio Feedback Successful Passport Read Three beeps will be played consecutively upon the successful reading of the electronic content from the pres...

Page 31: ...D 11 1 2 PC Configuration for USB 2 0 ActiveSync First Time Only Run the Datastrip_MT_USB Sync_Setup utility found on the User Manual CD After running the Sync setup you will be prompted to connect yo...

Page 32: ...ted by an internationally recognized logo shown below printed on the front cover The smart card integrated circuit in an ePassport stores The biographical data visually displayed on the data page of t...

Page 33: ...process Shown below are the typical motions for inserting and reading an ePassport The top sequence of photos shows the normal operation where the operator can continuously see the LCD screen and obse...

Page 34: ...e The document or credential to be scanned should then be inserted in the document slot and held against the glass platen The optical symbology to be read and decoded should be facing the glass platen...

Page 35: ...be in HID keyboard emulation mode with the default settings run DsCamerScannerHIDTest exe to verify this 12 3 2 2 Changing the Operating 12 3 2 3 Mode from HID Mode to Virtual Com Mode If the scanner...

Page 36: ...hat is mounted to the bottom of the terminal The contact smart card peripheral reads ISO 7816 smart cards The docking interface is replicated on the bottom of the peripheral so that the terminal equip...

Page 37: ...ional peripheral available for the DSV3 mobile terminals and can be adjusted to for each variant of the mobile terminal The docking station has the following attributes Wired I O Access Provides conve...

Page 38: ...nstalled in the correct forward or rear position the adjustment plunger may be adjusted to accommodate any installed optional peripherals The height of the adjustment plunger can be adjusted by pullin...

Page 39: ...up The battery may be completely discharged or may not be installed Open the battery access cover and verify that the battery is properly installed Use the external AC power adapter to operate the uni...

Page 40: ...Shoulder Strap and D Ring Connection Points For applications that require over shoulder carrying of DSV3 devices Ergonomically curved and padded shoulder area featuring non slip material on one side...

Page 41: ...trip for service upgrade or repairs please contact the tech support department by e mail or telephone An RMA will be issued and should be clearly marked on the outside of your shipping carton Please b...

Reviews: