background image

DI-1110 Hardware Manual

Controls, Indicators, and Connections

12

W

IN

D

AQ

 Remote Storage (Rcrd/D1)

To use a switch closure or TTL signal to begin recording data remotely, connect signal leads to the appropriate 
Remote Control Record terminals on the DI-1110 as shown below.

Once the switch closure or TTL signal is connected, activate Remote Storage (Record) through W

IN

D

AQ

 Acquisition 

Software. Storage to Disk may be automatically placed on the rising or falling edge of the trigger signal. Use the 
menu command 

Options

 > 

Remote Storage 1

 to set W

IN

D

AQ

 to begin recording on low-to-high transitions of the 

Record input. Use the menu command 

Options

 > 

Remote Storage 0

 to set W

IN

D

AQ

 to begin recording on high-to-

low transitions of the Record input.

W

IN

D

AQ

 Rate (Rate/D2)

Enable channel 10 to record Rate, or the number of falling-edge transitions per unit of time that are applied to this 
input. Click on 

Edit

 > 

Channels 

in the W

IN

D

AQ

 Acquisition menu to open the Channel Selection grid. Channel 10 is 

Signal -

www.dataq.com

+

-

+

-

+

-

+

-

D5

D4

D6

GnD

+5V

Power

Remote

Active

-

+

Ch1

-

+

Ch2

-

+

Ch3

-

+

Ch4

Model DI-1110

Analog Inputs (±10 VFS, ±100 V max)

+

-

+

-

+

-

+

-

Digital Ports (25 V @ 100mA max.)

Data Acquisition Starter Kit

Download software

at run.dataq.com

Rate/D2

Cnt/D3

Rcrd/D1

Evnt/D0

-

+

Ch5

-

+

Ch6

-

+

Ch4

-

+

Ch7

-

+

Ch8

Summary of Contents for DI-1110

Page 1: ...therwise without expressed written authorization from the com pany The distribution of this material outside the company may occur only as authorized by the company in writing DATAQ Instruments hardwa...

Page 2: ......

Page 3: ...o products that have been repaired or altered by persons other than DATAQ Instru ments employees or products that have been subjected to misuse neglect improper installation or accident DATAQ Instrume...

Page 4: ...iv...

Page 5: ...5 Connect the Instrument to Your Computer 6 4 Controls Indicators and Connections 7 Mini B USB Connection 7 Screw Terminals 7 DI 1110 Signal Connections 8 Connecting Signal Leads 8 Analog Inputs 9 Di...

Page 6: ......

Page 7: ...instrument protocol for programming the device in operating systems other than Windows WinDaq Unlock required to record more than four total channels when using WinDaq software Analog Inputs The DI 11...

Page 8: ...time at the full sample rate of the DI 1110 WINDAQ Waveform Browser playback software also known as WWB offers an easy way to review and analyze acquired waveforms A built in data file translator allo...

Page 9: ...dB Digital Ports Number of Ports 7 Type MOSFET switch Configuration Programmable as digital input or switch Programmed as a Switch Maximum drain voltage 25 V Maximum sink current 100 mA Count Rate In...

Page 10: ...3 LEDs Power Active Event Input connections Two 16 position screw terminal strips Power Power Consumption 1 0 Watt via USB interface Environmental Operating Temperature 0 C to 50 C 32 F to 122 F Opera...

Page 11: ...hat your unit must for any reason be sent back to DATAQ Instruments Install WINDAQ Software All software for the DI 1110 can be installed via a downloadable executable directly from the DATAQ Instrume...

Page 12: ...ard shortcut to access WINDAQ soft ware Connect the Instrument to Your Computer DI 1110 instruments can be connected to your computer s USB port using the provided USB cable No external power is requi...

Page 13: ...after signal cables are connected to the system under test since it will cause an electric shock To avoid ESD damage in handling the device take the following precautions Ground yourself with a ground...

Page 14: ...DI 1110 1 Insert the stripped end of a signal lead into the desired terminal directly under the screw 2 Tighten the pressure flap by rotating the screw clockwise with a small screwdriver Make sure th...

Page 15: ...100 mA Many of the ports also provide specific functionality in WINDAQ or a third party program Evnt D0 is for WINDAQ Remote Events This bit inserts an event marker in your data Rcrd D1 is for WINDAQ...

Page 16: ...ts Evnt D0 To use a switch closure or TTL signal to record WINDAQ Event Markers connect signal leads to the appropriate Remote Control Event terminals on the DI 1110 as shown below Dig In Dx Dx 10 4 7...

Page 17: ...nt input Event markers may also be placed in your data file manually by pressing the push button on the DI 1110 Instrument You must enable Remote Events in WINDAQ to use the button use the menu comman...

Page 18: ...1 to set WINDAQ to begin recording on low to high transitions of the Record input Use the menu command Options Remote Storage 0 to set WINDAQ to begin recording on high to low transitions of the Reco...

Page 19: ...000 2000 5000 10000 20000 and 50000 Hz are available Choose a range that comes closest to your expected full scale rate or frequency For example if you need to measure the output of a flow meter that...

Page 20: ...just one example that benefits from selecting this option For example if the 100 Hz range setting is selected and Cycles min is checked the full scale range is actually 6000 cycles per minute Please N...

Page 21: ...count value is 65 535 before the counter resets to zero automatically Use the Edit Reset Count command in WINDAQ Acquisition software to reset counts immediately to zero This feature is available in...

Page 22: ...able the digital inputs The Channel 9 channel box will display an I when enabled Channel 9 records and displays all the digital inputs even the state of the Rate and Count inputs if those channels are...

Page 23: ...ware Manual Controls Indicators and Connections 17 General Purpose Digital Outputs Take care when configuring the load to be switched to ensure that the digital port is not damaged Dx 5 V Dx 5 V Dx 5...

Page 24: ...side of the circuit as shown below Shunt Resistor Model R250 www dataq com D5 D4 D6 GnD 5V Power Remote Active Ch1 Ch2 Ch3 Ch4 Model DI 1110 Analog Inputs 10 VFS 100 V max Digital Ports 25 V 100mA ma...

Page 25: ...configurations You can also associate these values to a physical measurement such as pressure load flow torque etc Read the Help files for more information regarding Engineering Units Settings LED Ind...

Page 26: ......

Page 27: ...Go to https www dataq com products di 1110 to purchase the unlock code click on the Accesso ries tab or call 330 668 1444 Once purchased you will be given a Key code to enter into WinDaq 1 Start WinD...

Page 28: ......

Page 29: ...DI 1110 Hardware Manual Dimensional Drawing 23 6 Dimensional Drawing 1 612 5 500 4 750 4 250 0 750 2 625...

Page 30: ......

Page 31: ......

Page 32: ...TAQ Instruments Inc 241 Springside Drive Akron Ohio 44333 Telephone 330 668 1444 Fax 330 666 5434 E mail support dataq com Direct Product Links click on text to jump to page Data Acquisition Data Logg...

Reviews: