background image

Summary of Contents for DI-1100

Page 1: ...otherwise without expressed written authorization from the com pany The distribution of this material outside the company may occur only as authorized by the company in writing DATAQ Instruments hardware and software products are not designed to be used in the diagnosis and treatment of humans nor are they to be used as critical components in any life support systems whose failure to perform can r...

Page 2: ......

Page 3: ...to products that have been repaired or altered by persons other than DATAQ Instru ments employees or products that have been subjected to misuse neglect improper installation or accident DATAQ Instruments shall have no liability for incidental or consequential damages of any kind arising out of the sale installation or use of its products Service Policy 1 All products returned to DATAQ Instruments...

Page 4: ......

Page 5: ...pecifications 3 3 Installation 5 Installing WinDaq Software 5 Connecting the Instrument to Your Computer 6 4 Controls Indicators and Connections 7 Mini B USB Connection 7 Connect Input Signals 7 DI 1100 Signal Connections 7 Connect Signal Leads 8 Analog Inputs 8 WinDaq Remote Controls Digital Inputs 9 WinDaq Remote Events 10 WinDaq Remote Storage Record 12 4 20mA Current Loop Measurements 12 LED I...

Page 6: ......

Page 7: ...n operating systems other than Windows Analog Inputs The DI 1100 features four differential channel inputs located on a single sixteen position screw terminal block for easy connection and operation other terminals used for digital I O or reserved Note The DI 1100 does not support Gain Utilize the functionality of WINDAQ software to experience all the features encased in these small inexpensive in...

Page 8: ...ze acquired waveforms A built in data file translator allows the user to display multiple waveforms acquired by WINDAQ Acquisition software or any of a wide range of data acquisition packages The software s disk streaming design allows data files of any length to be graphically displayed rapidly in normal or reverse time directions Seven standard cursor based measurements frequency domain and stat...

Page 9: ...jection 80 dB Digital Inputs Number of ports 2 reserved Type MOSFET switch Threshold levels TTL compatible Absolute maximum applied voltage V 30 V dc Reserved Inputs Digital Inputs Digital In 0 WINDAQ remote events Digital In 1 WINDAQ remote start stop ADC Characteristics Resolution 12 bit Above zero ADC counts 2 047 Below zero ADC counts 2 048 Maximum sample rate per channel 40 kHz 1 enabled chan...

Page 10: ...0 non condensing Storage Temperature 20 C to 60 C 4 F to 140 F Storage Humidity 0 to 90 non condensing Physical Characteristics Enclosure Hardened Plastic Mounting Desktop bulkhead Dimensions 2 625D 5 5W 1 53H in 6 67D 13 97W 3 89H cm Weight 3 6 oz Software Support WINDAQ software OS support Check Online at https www dataq com products windaq windows compatibility Programming DATAQ NET Class Instr...

Page 11: ...lling WINDAQ Software All software for the DI 1100 can be installed via a downloadable executable directly from the DATAQ Instruments web site No CD is shipped with the device You may burn the executable onto a CD or flash drive to transport the software to a computer with no internet connection 1 Disconnect all DATAQ Instruments USB devices from your Computer 2 Download software at run dataq com ...

Page 12: ...instruments can be connected to your computer s USB port using the provided USB cable No external power is required Connect one end of the communications cable to the instrument port and the other to your PC s port Only one device may be connected at a time when using WinDaq Note Use a powered USB hub or a USB port on your PC Non powered USB hubs may not have sufficient power to run the instrument...

Page 13: ...alog channels 1 4 10VFS 100V transient Max Remote Control Event Digital Input bit 0 Remote Event Marker Remote Control Record Digital Input bit 1 Remote Start Stop Reserved NC No connection reserved www dataq com Analog In Channels 1 4 Reserved no connection Digital In Channels Power Active and Remote LEDs Event Marker Push Button Mini B USB Connection SD Card Slot not used in DI 1100 Bulkhead Mou...

Page 14: ...ll screwdriver Make sure that the pressure flap tightens only against the signal wire and not the wire insulation Do not over tighten 3 Tug gently on the signal lead to ensure that it is firmly secured When an input signal is connected and WINDAQ Acquisition software is run WINDAQ s real time display immedi ately reveals the input waveform on your computer s monitor Analog Inputs Four differential...

Page 15: ... contains 2 digital inputs designated for WINDAQ Remote Events inserts an Event Marker and Remote Storage Record data www dataq com Signal Signal Power Remote Active Ch1 Ch2 Ch3 Ch4 Model DI 1100 Data Acquisition Starter Kit Reserved Analog Inputs 10 VFS 100 V max Event Record Remote Control Event Download software at run dataq com 1M 20K 3 3V 1M 10K 1 5V 10K Digital In ...

Page 16: ...emote Events through WINDAQ Acquisition Software Events may be automatically placed on the rising or falling edge of the trigger signal Use the menu command Options Remote Events to set WINDAQ to place event markers on low to high transitions of the Event input Use the menu command Options Remote Events to set WINDAQ to place event markers on high to low transi tions of the Event input Switch Clos...

Page 17: ...and Options Remote Events or Options Remote Events An example event marker in a WINDAQ data file is shown below Please Note Event Markers do not display in the real time WINDAQ acquisition software they only display in the WINDAQ playback software WWB www dataq com Power Remote Active Ch1 Ch2 Ch3 Ch4 Model DI 1100 Data Acquisition Starter Kit Reserved Analog Inputs 10 VFS 100 V max Event Record Re...

Page 18: ...o begin recording on low to high transitions of the Record input Use the menu command Options Remote Storage 0 to set WINDAQ to begin recording on high to low transitions of the Record input 4 20mA Current Loop Measurements Use the following diagram for 4 20mA current loop measurement connections Signal Signal www dataq com Power Remote Active Ch1 Ch2 Ch3 Ch4 Model DI 1100 Data Acquisition Starter...

Page 19: ...h as pressure load flow torque etc Read the Help files for more information regarding Engineering Units Settings LED Indicators The DI 1100 provides three LEDs for instrument status and notification Power Green LED indicates power is applied via the USB cable Active Indicates the device is in use either by WINDAQ Acquisition Software or a custom user developed program Remote Green LED indicates wh...

Page 20: ......

Page 21: ...DI 1100 Hardware Manual Dimensional Drawing 15 5 Dimensional Drawing 1 612 5 500 4 750 4 250 0 750 2 625 ...

Page 22: ......

Page 23: ......

Page 24: ...ATAQ Instruments Inc 241 Springside Drive Akron Ohio 44333 Telephone 330 668 1444 Fax 330 666 5434 E mail support dataq com Direct Product Links click on text to jump to page Data Acquisition Data Logger ...

Reviews: