Dataprobe RSS-16 Installation And Operation Manual Download Page 39

 

 

 
 
RSS_v180808n 

RSS Series 

 

 

Page 39 

 

8.3.2. 

Frame Ground Switching – Model AB-D25-R 

 
Jumper selection allows Pin 1 Frame Ground to be either switched or tied 
together and non-switched.  Pin 1 can also be tied to the Frame of the 
Chassis, or left isolated from the chassis. 
 
 

8.3.3. 

Signal Ground Switching 

 
An additional set of jumpers provides the same switched/common, isolated or 
grounded for Signal Ground.  These jumpers control Pin 7 in the D25 model and Pin 5 in the D15 and D9 
models.  The circuit is the same as shown above replacing Pin 1 for the correct pin and SG Signal Ground for 
FG, Frame Ground. 

8.4. 

Indicators 

 
Two Red LEDs indicate Switch status A or B.  LED's are driven by extra relay contacts. 

8.5. 

Manual Switches 

 
Manual toggle switch on each card.  These are momentary switches.   Also controlled by 

RSS-16

 front panel 

Gang Control pushbuttons when the card’s jumper is configured for Gang control. 

8.6. 

Relays 

Sealed Telephone relays. Gold clad contacts. Maximum Contact Current: 2 Amps @ 30 VDC  
Special DS-3 and NET models: Hi Freq.  Speeds up to 1 Gig Hz. 

 

8.7. 

Interface Wiring 

 

8.7.1. 

AB-D25-R 

Conectors:   

 

25 Pin D’Subminiature, Female 

Leads Supported: 

All 25 Pins Switched 

Additional Information:  Optional Jumper Configuration for 
 

 

 

Unswitched Frame Ground Pin 1 (See Section 8.4.2)  J10 

 

 

 

 and Signal Ground Pin 7 (See Section 8.4.3) J11 

 
 

Summary of Contents for RSS-16

Page 1: ...nternal power supply modules in a compact 4U high 19 inch chassis The RSS 3 supports up to 3 AB switch cards 1 control interface card and 1 internal power supply module in a 1U chassis with removable...

Page 2: ...Interface 12 4 10 Configuration IPC 16 R 13 4 11 Setting other Parameters 14 4 12 Operation 15 4 13 Command Line Interface 16 4 14 Web Browser Operation 21 4 15 SNMP Manager Control 23 4 16 Escape Seq...

Page 3: ...in the end product for the top and bottom openings Un incendie appropri et armoire lectrique doivent tre fournis dans le produit final pour les ouvertures sup rieure et inf rieure If any of the card s...

Page 4: ...utes les sources d alimentation doivent tre d connect s avant l entretien pour viter tout risque de choc 2 3 RSS 3 Chassis Item 1150102 The RSS 3 Chassis mounts in standard 19 equipment cabinets Rack...

Page 5: ...ard or down for the B position With no card in a slot there will be no toggle switch 2 7 Gang Control Switches RSS 16 The RSS 16 chassis has three pushbutton switches for simultaneously controlling al...

Page 6: ...es Dataprobe offers the following internal supply modules for the RSS series 1930084 100 240 VAC 50 60 Hz 1930083 100 240 VAC 50 60 Hz Power Factor Corrected 1930086 42 60 VDC 1930081 24 VDC External...

Page 7: ...nstalls from rear of chassis 3 2 4 AC Input connector IEC 320 C14 on rear panel 3 3 Power Supply 1930086 Converts 48 VDC to 24VDC Single Slot Dual Redundant Capable 3 3 1 INPUT POWER Nominal 48 VDC Ra...

Page 8: ...l Connection Panel item 1930081 Redundant power can be added by connecting an external power supply to the DC power connector provided on the control card using Connector Kit item 1940164 LED indicato...

Page 9: ...t be installed in restricted access areas such as dedicated equipment room or electrical closet in accordance with the United States National Electrical Code A RESTRICTED ACCESS LOCATION is a location...

Page 10: ...witching system Serial IPC 16 R Only The serial port on the IPC 16 R provides direct terminal access or via modem The A B Cards are controlled either by a menu selection or by command line strings esc...

Page 11: ...redundant power Mating Connector kit 1940164 Gang Expansion RJ11 connection for connection to additional chassis for large gang switching applications Serial Port RS 232 port for out of band access to...

Page 12: ...e 9600 19200 38400 57600 and 115200 bits per second Character format is fixed at 8 Data Bits No Parity One Stop Bit 8 N 1 4 7 1 Factory Defaults 9600 8 Data Bits No Parity One Stop Bit 9600 8 N 1 4 8...

Page 13: ...onfiguration of the IPC 16 R involves the following steps Setting The IPC 16 R s IP Address Setting additional configuration parameters 4 10 1 Setting I P Address The IPC 16 R comes with factory insta...

Page 14: ...dress or current IP address 192 168 1 xxx If this is not the case use one of the other methods To connect to the IPC 16 R using telnet run your telnet client program provided with your operating syste...

Page 15: ...t to the IPC 16 R For example if the IP address of the IPC 16 R is 192 168 1 254 and you have changed the web port to 8800 then you would need the following URL to access the IPC 16 R http 192 168 1 2...

Page 16: ...Enabled Act 1 NewYork Yes A 2 Boston Yes A 3 Providence Yes A 4 Philadelphia Yes A 5 Baltimore Yes B 6 WDC_East Yes A 7 WDC_West Yes A 8 Atlanta Yes A 9 Miami Yes B 10 Seattle Yes A 11 Portland Yes B...

Page 17: ...10 10 10 70 Subnet 255 255 255 0 Gateway 10 10 10 7 DNS1 0 0 0 0 DNS2 0 0 0 0 Ok RSS 16 set ipmode static dhcp Sets the IP Mode Static The IP address is set manually DHCP The IP Address is set by DHCP...

Page 18: ...Set the telnet enable flag Default set console telnet port 1 65535 Set the telnet port 23 get SNMP Get network SNMP settings RSS 16 get snmp Read Community public Write Community private Manager IP A...

Page 19: ...no Set if Web Encryption HTTPS is required no get escape Get escape sequence settings RSS 16 get escape Escape Enabled Yes Escape Port 9100 Ok RSS 16 set escape enabled yes no Set escape sequence ena...

Page 20: ...d 1 get all Current Card Values Card ID 1 Card Name NewYork Enabled Yes Active Port A Ok RSS 16 Card 1 get name set name 0 20 characters Set card name get enabled set enabled yes no Set card enabled f...

Page 21: ...68 1 254 You may wish to bookmark this location and rename the bookmark for easy reference You will be prompted for a User Name and Password The User Name is not used and any or no characters can be e...

Page 22: ...page was displayed To obtain the latest status click on the Refresh button If cards are not installed in the system their status will be reported as Position A To avoid confusion use the Disable feat...

Page 23: ...ed through the Setup Menus Once connected use the Send function to send the commands to the IPC 16 R and the Recv function to receive the IPC 16 R s response For the serial port of the IPC 16 R connec...

Page 24: ...24 If the queried card has been disabled then no response will be transmited In response to the Query All command 16 response messages will be sent All invalid commands will be ignored No response eve...

Page 25: ...1 254 you may need to change this address Consult your Network Administrator to determine the appropriate IP address The IP address can be set in any of four ways Web Browser via the Set up Page Auto...

Page 26: ...the MAC Address of the IPC 1 R The MAC Address of the IPC 1 R is located on bottom of the unit Example arp s 192 168 7 203 00 50 c2 05 01 c1 enter new IP addr MAC addr 2 Ping the IPC 1 R to program th...

Page 27: ...as been changed Default Usernames admin user Default Passwords admin user IPC 1 R also uses an inactivity timer for security When there is no activity for 2 minutes the connection is closed and the pa...

Page 28: ...is to prevent accidental lockout by leaving the browser open If the Auto Ping feature is in use this page will also display its status OK or Triggered and the number of times it has been triggered OK...

Page 29: ...e Page as well as the Status Name for the A and B switch positions IP Set the IP address IP acquisition mode Port Settings and SSL AutoPing Set the IPC 1 R for automatic operation based on device avai...

Page 30: ...d A Reboot button will appear on the bottom of the page This will automatically reboot the IPC 1 R and redirect the browser to the new address port AutoPing This page sets the unit for automatic opera...

Page 31: ...manual toggle switch SNMP or TCP Messaging Switch Return IP A Switch to B on ping loss and back to A when ping response resumes Hunt for Ping IP A On loss of ping switch to B and look for ping respon...

Page 32: ...nloaded from the Dataprobe website and installed on your units Check http dataprobe com support rss series welcome for the latest release To install the firmware click on Update from the Setup page Fo...

Page 33: ...wiring connected to the IOC card may cause unintended switch card changes Make sure to use the screws provided to secure the card in the chassis before connecting cables 6 2 Status and Control Connect...

Page 34: ...0 45 21 46 22 47 23 48 24 49 25 50 Control Pin Function Card Slot 1 1 Switch to A 26 Switch to B Card Slot 2 2 Switch to A 27 Switch to B Card Slot 3 3 Switch to A 28 Switch to B Card Slot 4 4 Switch...

Page 35: ...the chassis in either of the two control card slots only If an IPC R 16 network card is also used the IOC card should be installed in 2 nd control card slot which is the 3 rd slot from the left in the...

Page 36: ...in and Gang Out connectors Use standard RJ11 RJ12 6 conductor modular cable between jacks Pin Designation Function Feedback Status This pin is open relative to ground for Position A and closed to grou...

Page 37: ...aced with blank plates Model Item Description Notes AB D25 R 1110200 D25 Connectors for RS 232 RS 530 etc AB D15 R 1110212 D15 Connectors for X 21 AUI etc AB D9 R 1110206 D9 Connectors for RS 232 RS 4...

Page 38: ...rds may be inserted and removed with the power on hot insertion removal Cards are secured in chassis with screws at right and left of each panel Cables for the Common A B circuits are attached to the...

Page 39: ...G Signal Ground for FG Frame Ground 8 4 Indicators Two Red LEDs indicate Switch status A or B LED s are driven by extra relay contacts 8 5 Manual Switches Manual toggle switch on each card These are m...

Page 40: ...ns Switched Additional Information Optional Jumper Configuration for Signal Ground Pin 7 See Section 8 4 3 J11 8 7 4 AB 2RJ8 R Conectors 8 Wire Modular Jack Leads Supported All 8 Wires Additional Info...

Page 41: ...all Jumper as indicated for Non Switched Pin Connector A Connector B 25 JP2 JP1 50 JP3 JP4 Pin Connectivity V Switched W Switched X Switched Y Switched Z Not Supported AA Switched BB Switched CC Not S...

Page 42: ...intable ASCII characters and MUST not exceed 20 characters in length rss16CardPosition 1 3 6 1 4 1 1418 1 1 2 1 3 rss16CardIndex This read write variable can be used to set or get the position of any...

Page 43: ...eger where 0 ok 1 fail 9 1 Trap Definitions ps1Failed specific 1 This trap is sent when ever power supply 1 fails It carries not variable bindings ps1Ok specific 2 This trap is sent when ever power su...

Page 44: ...anty is obtained by contacting your Authorized Dataprobe Reseller THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT MISUSE ABUSE OR NEGLECT SELLER MAKES NO EXPRESS WARRA...

Reviews: