Firmware Upgrades 

The iPIO-8 can be field upgraded.  Find the latest version or special purpose versions at 

http://dataprobe.com/support-ipio8/

 

 

Upgrading the firmware with a minor upgrade (i.e. 1.01.xx  to 1.01.yy) will not alter the 
user defined settings.  Major upgrades may or may not reset the iPIO-8 to factory 
defaults.  Check the release notes for the upgrade before making changes to you iPIO-8. 

 
 

1)  Run the Device Management Utility, available at the link above.  If the iPIO-8 you would like to 

upgrade is not visible in the list box, either 

 
 

Select Device | Discover from the menu to locate iPIO-8 units on the local network, or 

 

Select Device | Add from the menu to add the IP address of the iPIO-8. 

 
 

Once the device is displayed in the list, highlight it 

 

2)  Select Manage | Upgrade Firmware 

 

 

Enter User Name 

root

 and the Password for the Administrator.   (default is 

admin

 
Enter the filename of the firmware, or 
click Browse and find the file of the 
firmware file to be used.  iPIO-8 
firmware uses the extension 

.ipu

  If 

you don’t see any files of that type, 
make sure the ‘Files of type’ box is set 
for iPIO-8 or All Files. 
 
Click OK when all the details are 
entered. 
 

3)  The upload will begin, and a 

progress bar will be displayed. 

 
4)  When the firmware upload is 

completed, 

WAIT 2 Minutes.

  

The iPIO-8 will automatically 
reset and be ready for use. 

 
 

Summary of Contents for iPIO-8

Page 1: ...Multiple iPIO 8 devices can communicate amongst themselves to transport I O information across the network Each iPIO 8 has eight controllable form C relays and eight digital inputs Each channel of the iPIO 8 is independently configurable allowing selection of what IP addresses to deliver to and on what channel Highly flexible telemetry systems can be developed with these simple devices REF ipio8_v...

Page 2: ...PIO 8 relays using the screw terminals as illustrated Relays are Form C Connect to the Common C Normally Closed NC and Normally Open NO as marked When the iPIO 8 relay is in the Open Condition the Common is connected to the Normally Open In the Closed state the Common and Normally Closed are connected Relay Specifications Rating resistive 0 5 A 120 VAC or 1 A 24 VDC Maximum Carrying Current 2 A Ma...

Page 3: ...Network Connect the network to the iPIO 8 with the Cat 5 cable provided or suitable replacement The Network connector on the iPIO 8 has two LED indicators The orange LINK LED indicates a successful connection to the network The Green ACT LED blinks to display network activity LED Indicators Pwr Power On indication Rmt Remote Communication Status indication LED OFF No Remote Units Programmed LED ON...

Page 4: ...y Open LED ON Relay Closed During power up sequence LEDs will be off until boot complete then flash once then set to their current status Link Network Connected Act Network Activity During power up sequence Act LED will be solid on until boot process is complete After boot LED blinking indicates network activity ...

Page 5: ...es the iPIO 8 device the user is connected to This location ID is settable Each input output and remote device is defined by a user selectable name Inputs and outputs can also be assigned names for Open and Closed statuses as well as background and text colors for each All configurations are accomplished via the Setup button at the left of the screen If the iPIO 8 is programmed to communicate with...

Page 6: ...he user has access only to the status and control page The Administrator also has access to the setup pages Network Setup The iPIO 8 provides two methods for setting the IP Address 1 Static 2 DHCP Select Static Mode from the drop down list and fill in the IP Address Subnet Mask and Gateway as provided by your network administrator Click save to save the changes You will then be prompted to reboot ...

Page 7: ...tion to secure status and control messages To use AES enter a AES Passphrase up to 16 characters and enable AES with the checkbox Any additional iPIO 8 that connects to this device will need to use the same Passphrase as set here See Remote Setup for entering the Passphrase of a remote iPIO 8 Use DxP Username and Password Older DxP supported devices do not use username and password pairs in the pr...

Page 8: ...p on Change Set which events will generate SNMP Traps Input Email on any input change Relay Email on any relay change Communication Email on any change in communication status to the remotes Configuration Email on any configuration change To use the SNMP download the iPIO MIB at http dataprobe com support ipio8 Input Setup Each of the eight inputs is represented by a tab with its name Click on the...

Page 9: ...ddress and Port if changed from default 9100 when setting up the remote AES Encryption can be used to secure communications with the remote Enter the Passphrase that matches the remote device and check the AES checkbox Remote Relays One relay on the local iPIO 8 can be used as an alarm for link failure When used the Alarm relay will be energized Common to Normally Closed connected when the link is...

Page 10: ...ote iPIO 8 When the remote iPIO 8 is set up use this button to coordinate the local inputs with the remote relays iPIO 8 units continually communicate to coordinate inputs and outputs If one or more remotes are programmed the RMT LED on the front of the iPIO 8 will be solid on If any remotes fail to communicate the LED will flash and the alarm relay if programmed will Open Click refresh or refresh...

Page 11: ...nk supervision add all the reporting sites as remotes in the central unit and set an alarm relay Application 3 Multi Site Event Distribution In this application one central sites broadcasts status information to multiple remote sites Set all remote sites as remotes in the central unit To get link supervision at the remote sites add the central unit as a remote and set an alarm relay in each locati...

Page 12: ...e Discover from the menu to locate iPIO 8 units on the local network or Select Device Add from the menu to add the IP address of the iPIO 8 Once the device is displayed in the list highlight it 2 Select Manage Upgrade Firmware Enter User Name root and the Password for the Administrator default is admin Enter the filename of the firmware or click Browse and find the file of the firmware file to be ...

Page 13: ...eset Hardware Reset Inputs 8 Digital Inputs Dry relay switch closures or 3VDC to 30 VDC Grounds common Control Relay Current Maximums 0 5A 120VAC or 1A 24VDC Switching Power 60VA Max 50uW Min Switching Voltage 120VAC or 60VDC Max 1VDC Min Switching Current 1A Max 1mA Min Resistance 100 milliohms initial value Operations 5 Million mechanical 100K at maximum load Network HTTP Web Server SSL Secure S...

Page 14: ...ervice under this Warranty is obtained by contacting your Authorized Dataprobe Reseller THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT MISUSE ABUSE OR NEGLECT SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH HEREIN EXCEPT TO THE EXTENT PROHIBITED BY LAW ALL IMPLIED WARRANTIES INCLUDING ALL WARRANTIES OF MERCHANT ABILITY OR FITNESS FOR...

Reviews: