![Dataprobe iBootBar iBB-DC8 Installation And Operations Download Page 27](http://html1.mh-extra.com/html/dataprobe/ibootbar-ibb-dc8/ibootbar-ibb-dc8_installation-and-operations_3712613027.webp)
V180808N
iBB-DC8 Manual
Page 27
9.3.3. CLI Operation and Setup:
To view the status of any of the AutoPing channels, issue the
get autoping <1-16>
command.
iBootBar > get autoping 1
IP Address: 192.168.1.7
Action: Cycle
Frequency: 30
Count: 3
Outlet: Cabinet_1 - Firewall
Status: OK
OK
iBootBar >
To configure the AutoPing, use the following commands:
set autoping <1-16> ipaddress <dotted decimal>
set autoping <1-16> action <action>
set autoping <1-16> frequency <1-999>
set autoping <1-16> count <1-99>
set autoping <1-16> device <name/#1-16> outlet <1-8>
set autoping <1-16> group <name>
9.4.
SSL Security
The iBootBar can provide Secure Socket Layer (SSL) encryption on the web interface. Enable this feature using
the
set
web ssl yes
command from the Telnet / Serial interface.