background image

 

 

14.  Technical Support and Warranty 

 
Seller  warrants this product, if used  in accordance  with all applicable  instructions, to be free from original  defects in 
material and workmanship for a period of 

Three Years

 from the date of initial purchase.  If the product should prove 

defective within that period, Seller will repair or replace the product, at its sole discretion.  Repairs may be made with 
new or refurbished components and replacements may be new or refurbished at the Sellers sole discretion. Repaired 
or replaced units shall be warrantied for the balance of the original warranty, or 90 days, whichever is greater. 
 

If Purchased from Dataprobe Inc.; 

Service under this Warranty is obtained by shipping the product (with all charges 

prepaid)  to  the  address  below.    Seller  will  pay  return  shipping  charges  within  the  United  States.    Call  Dataprobe 
Technical Service to receive a Return Materials Authorization (RMA) Number prior to sending any equipment back for 
repair.  Include all cables, power supplies, accessories and proof of purchase with shipment. 
 

If purchased from an Authorized Dataprobe Reseller;

 Service under this Warranty is obtained by contacting your 

Authorized Dataprobe Reseller.   
 

THIS  WARRANTY  DOES  NOT  APPLY  TO  NORMAL  WEAR  OR  TO  DAMAGE  RESULTING  FROM  ACCIDENT, 
MISUSE,  ABUSE  OR  NEGLECT.    SELLER  MAKES  NO  EXPRESS  WARRANTIES  OTHER  THAN  THE 
WARRANTY  EXPRESSLY  SET  FORTH  HEREIN.    EXCEPT  TO  THE  EXTENT  PROHIBITED  BY  LAW,  ALL 
IMPLIED  WARRANTIES,  INCLUDING  ALL  WARRANTIES  OF  MERCHANT  ABILITY  OR  FITNESS  FOR  ANY 
PURPOSE  ARE  LIMITED  TO  THE  WARRANTY  PERIOD  SET  FORTH  ABOVE;  AND  THIS  WARRANTY 
EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES. 
 

Some  states  do  not  allow  limitations  on  how  long  an  implied  warranty  lasts,  and  some  states  do  not  allow  the 
exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to 
you.    This  warranty  gives  you  specific  legal  rights,  and  you  may  have  other  rights  which  vary  from  jurisdictions  to 
jurisdiction. 
 

WARNING:

 The individual user should take care to determine prior to use whether this device is suitable, adequate or 

safe  for  the  use  intended.    Since  individual  applications  are  subject  to  great  variation,  the  manufacturer  makes  no 
representation or warranty as to the suitability of fitness for any specific application. 
 
 

Dataprobe Inc. 
Technical Support:  201-934-5111 

[email protected]

 

www.dataprobe.com/support.html 

 

Summary of Contents for iBoot PoE-P

Page 1: ...ty 31 Congratulations on purchasing the best network controlled power switch available The iBoot PoE P provides you the ability to reboot crashed devices automatically or with the click of a mouse Be...

Page 2: ...Reboot iBoot PoE P has a web server built in as well as the ability to be managed through the iBoot Cloud Service A simple Web browser interface makes it easy to control power from anywhere in the wo...

Page 3: ...it is also possible to turn ON or OFF the PD when the trigger conditions are met See Section 5 5 On AutoPing Setup Traffic Monitor Traffic Monitor measures the bandwidth utilization and reboots the PD...

Page 4: ...mputer control URL Control You can send a single URL to the iBoot PoE P containing all the information necessary to query or change the power status This makes it easy to create a single button on you...

Page 5: ...ctor Auto Configuration can also be initiated via the web page setup See Section 5 5 2 2 Hardware Connections iBoot PoE P supports 10 100 1000 Ethernet using the cable supplied or other suitable unshi...

Page 6: ...Voltage on all pins 1 DC DC 2 DC DC 3 DC DC 4 DC DC 5 DC DC 6 DC DC 7 DC DC 8 DC DC Power Output on the PoE OUT connector will be identical to whatever mode is used on the NET IN connector 2 4 Mountin...

Page 7: ...he iBoot PoE P Obtain and use the DMU 1 Download the latest version of the DMU at dataprobe com support iboot poe Run DMUSetup exe 2 Run the DMU Note The IP address can only be set within the first tw...

Page 8: ...utton Get all the details on the DMU at http dataprobe com support dmu 3 3 Other ways to set the IP Address 1 Web Browser via the Set up Page See Section 5 2 Command Line Interface See Section 9 3 4 A...

Page 9: ...setup or Command Line Interface See Section 5 5 for an explanation of these settings AutoPing Setting Address IP Address of Powered Device Frequency 10 Seconds Fail Count 3 Mode Single Action Cycle Re...

Page 10: ...tes Setting to zero disables the timeout feature When there is no activity for the set time in minutes the user is automatically logged out and the username and password will need to be entered again...

Page 11: ...ded If the iBoot PoE P is connected to a time server see Section 5 4 The Home page will also show the five most recent history events including the Outlet Action User and Time Date of each event The i...

Page 12: ...not significant The user and password are not required when Auto Login feature is enabled see Section 5 7 for security options Examples http 192 168 1 254 s 1 u user p user Turn the outlet on for the...

Page 13: ...emote firmware upgrades of the iBoot PoE P When this box is unchecked firmware upgrades will not be allowed Auto Logout This setting sets the automatic logout for inactivity on both the web and telnet...

Page 14: ...able Cloud Services This setting enables the iBoot PoE P for iBoot Cloud Services iBCS iBCS allows the iBoot PoE P to be monitored and controlled from a web portal from any browser It allows multiple...

Page 15: ...oth AutoPings need to exceed their fail count to trigger the Action With OR the Action will be triggered if either AutoPing fails Action Select from None AutoPing is paused No Ping tests will be perfo...

Page 16: ...fic Subsequent reboots will occur when the time equals the Restart Time plus the Fail Time Number of Cycles Set the number of reboots to attempt for a single failure event Minimum Traffic Sets the min...

Page 17: ...de supports both User and Admin users Each user has a settable password Auto Login This mode does not require a username of password for the User level operation No login challenge will be required fo...

Page 18: ...will not allow programming for On Follow Off Latch or Off Follow If a Schedule Settings event has action for Off it will be reprogrammed for On Schedule Settings will not allow programming for action...

Page 19: ...ice name when on the local network By default the name is iBoot PoE P xxxx where the xxxx is the last 4 segments of the MAC address for your iBoot PoE P When you reprogram the name of the device a reb...

Page 20: ...Boot firmware may be made available and necessary to keep current with the cloud development The full Terms of Service of the iBoot Cloud Service is available here While the Cloud Service is in Beta s...

Page 21: ...click on Add Device and enter the activation code in the field provided Congratulations You are now on the cloud d iBCS Main Page The iBCS main web page provides the ability to control your iBoot PoE...

Page 22: ...to Password Enter the admin or user password and press Enter The prompt will change to iBoot This indicates successful login Enter commands as needed When done enter the logout command Note The telnet...

Page 23: ...etwork This command will return all the network settings as shown below Mode DHCP IP Address 192 168 1 254 Subnet 255 255 255 0 Gateway 192 168 1 1 DNS 8 8 8 8 HTTP Port 80 Linkback URL Telnet Port 23...

Page 24: ...decimal or name This command is used to set the address of AutoPing 1 or AutoPing 2 Use IP Address or domain name set autoping 1 2 frequency 1 999 This command is used to set the frequency how often t...

Page 25: ...the stop disable time 00 00 get traffic monitor Traffic Monitor Enabled or Disabled Fail Time in seconds Restar Time in seconds Number of Cycles Minimum Bandwidth as programmed Maximum Test enabled d...

Page 26: ...d to set the Address of a network time server ip or FQDN time nist gov get time Displays the current time and time server settings Current Time 07 30 2015 10 41 05 Timezone 5 DST Enabled Starts the 2n...

Page 27: ...at the user is presented with Password This prompts the user to enter his password iBoot This is the prompt that will be displayed after the user has successfully logged in iBoot Reboot Required This...

Page 28: ...es for the upgrade before making changes to you iBoot PoE P 1 Insure that the Upgrade Enable checkbox is checked in the Network Setup web page of the iBoot PoE P 2 Run the Device Management Utility av...

Page 29: ...e output status 5 Seconds push Reset to Factory Defaults Hold the button in until the Outlet LED is blinking then release Hold in while and Power up the iBoot Recovery Mode Allows upload of new firmwa...

Page 30: ...ce FCC Part 15 Class B CE Emission EN 55032 2012 AC 2013 CISPR 32 2012 Class B AS NZS CISPR 32 2013 EN 61000 3 2 2014 and EN 61000 3 3 2013 Immunity EN 55024 2010 A1 2015 IEC 61000 4 2 2008 IEC 61000...

Page 31: ...r this Warranty is obtained by contacting your Authorized Dataprobe Reseller THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT MISUSE ABUSE OR NEGLECT SELLER MAKES NO EX...