Dataprobe iBoot-Exp Manual Download Page 4

 

 

V100921e 

iBoot-EXP  

 

 

5. Specifications 

5.1. 

Physical 

Height 

 

2.0” 

60mm 

 

Page 4

Width 

3.2” 82mm   

Depth 

4.2” 107mm    

Weight 

8.6 oz 244g 

MTBF 

 540,000 Hours           

Temperature 

0 – 50 degrees C 

5.2. 

AC  

Input 

IEC 320 C14 

Input Cord  

16AW

UL/CSA/VDE Rated 
(1.25m

GX3C 10A 25

m2X3C) 

Voltage Range 

Auto S

40 VAC 

ensing 105-2

Switched 

IEC 3

Receptacle 

20 C13 

Capacity 

12 A Max at 105-125 VAC,    
10 A Max at 210-240 VAC 

5.3. 

Power and Control Connections 

Four position removable screw terminals.   
18AWG maximum.   
Maximum distance to iBoot-G2+    
330feet/100m using 24AWG wire. 

+V 

Ex 12VDC input  provided by 
iBoot G2+ 

Control Input.  Contact closure or open 
collector transistor circuit only 

Status feedback.  Open collector circuit.  

 Power 

Open = Power On, Grounded =
Off 

5

 File No. 188

 

.4. 

Compliance   

UL/cUL 

UL60950  Listed I.T.E 

CE 

Di
93
E
E

rectives 89/336/EEC, 92/31/EEC and 

/68/EEC 

 

N 60950: 3rd Edition

 

N 55022: 1998 Class B

 

FCC

 

Part 15 Class B

 

6. Important Safety Instructions 

When using
persons, incl

 this produ

 precautions should always be followed to r

tric shock, and injury to 

uding the following: 

understand all in

2. 

Follow all warnings and ma

3. 

Unplug this product from the w

 liquid cleaners 

or aerosol cleaners.  Use a damp cloth for cleaning. 

4. 

Do not use this product in an outdoor environment or near water, for example, near a 
bath tub, wash bowl, kitchen sink, or laundry tub, in a wet basement, or near a 
swimming pool. 

5. 

Do not place this product on an unstable cart, stand, or table.  The product may fall, 
causing serious damage to the product. 

6. 

Slots and openings in this product and the back or bottom are provided for ventilation 
to protect it from overheating; t
openings should never be blocke
other similar surface.  This prod
heat register.  This product shoul
ventilation is provided. 

rounding type plug, a plug having a third 

(grounding) pin.  This plug will only fit into a grounding type power outlet.  This is a 

rt the plug into the outlet, contact your 

efeat the safety purpose of the 

 

1

t overloa

n cords as this can result in the risk of fire or 

electric shock.  

11.  Never push objects of any kind into this product through slots as they may touch 

dangerous voltage points or short out parts that could result in a risk of fire or 
electrical shock.  Never spill liquid of any kind on the product. 

12.  To reduce the risk of electrical shock, do not disassemble this product, but take it to a 

qualified serviceman when some service or repair work is required.  Opening or 
removing covers may expose you to dangerous voltages or other risks.  Incorrect re-
assembly can cause electric shock when the appliance is subsequently used.  

13.  Unplug this product from the wall outlet and refer servicing to qualified service 

 conditions: 

 cord or plug is damaged or frayed. 

 into the product. 

 exposed to rain or water. 

d)   If the product does not operate normally by following the operating instructions.  

often require extensive work by a qualified technician to restore the product to 
normal operation. 

 

15.  

 

ct, basic safety

educe the risk of fire, elec

 

1

Read and 

structions. 

rked on the product.  

all outlet before cleaning.  Do not use

 

0.  Do no

d wall outlets and extensio

hese openings must not be blocked or covered.  The 

d by placing the product on the bed, sofa, rug, or 

uct should never be placed near or over a radiator or 

d not be placed in a built-in installation unless proper 

personnel under the following
a)    When the power supply
b)    If liquid has been spilled
c)   If the product has been

7. 

This product should be operated only from the type of power source indicated on the 
marking label.  If you are not sure of the type of power supply to your home, consult 
your dealer or local power company. 

This product is equipped with a three wire g

Adjust only those controls that are covered by the operating instructions 
because improper adjustment of other controls may result in damage and will 

8

e)   If the product has been dropped or has been damaged. 
f)  

If the product exhibits a distinct change in performance. 

safety feature.  If you are unable to inse
electrician to replace your obsolete outlet.  Do not d

14.  Avoid using a telephone (other than a cordless type) during an electrical storm.  

There may be a remote risk of electric shock from lightning. 
Do not use the telephone to report a gas leak in the vicinity of the leak. 

grounding type plug.  Do not use a 3-to-2 prong adapter at the receptacle; use of this
type adapter may result in risk of electrical shock and/or damage to this product. 

9. 

Do not allow anything to rest on the power cord.  Do not locate this product where the 
cord will be abused by persons walking on it.

16.  Do not exceed the maximum output rating of the auxiliary power receptacle

Save These Instructions 

Reviews: