INTRODUCTION

The 4 Position Code Activated Switch, 

Model 4P-MAS

 allows one master RS-232 port to be selectively

switched to any of four RS-232 devices, designated A through D.  Typically, the 4P-MAS is used to
allow one modem to access the configuration or out-of-band management ports of four remote devices
(see Figure 1A).  Three modes of operation allow the selection of the port to be connected.

Menu Selection

The  4P-MAS selects the port to connect to the master based on menu selections.
The menu system allows convenient naming of each port, and setup of all 4P-MAS
parameters.

Lead Control

This option allows any of the four ports can access the master port by raising its
Request To Send (RTS) or Data Terminal Ready (DTR) control lead.  This capability is
in addition to the menu selection as described above.

Manual Control

A front panel push-button allows local control of port selection.

There are four LED's on the front of the 4P-MAS to indicate which port is connected to the master.
There are four DB25S female connectors on the rear panel for the switched ports, (designated A-D) and
one DB25P male connector for the Master Port. The 4P-MAS also supports an internal modem option.
Dataprobe supplies modems from 2400 bps to 33.6 Kbps.  This modem can be factory or field installed.
Figure 1 illustrates a typical system using the 4P-MAS.

Internal or 
External 
Modem

Master
Port

A

B

C

D  

To DCE

To 4 DTEs

REF: CAS\4P-MAS_V980326R.DOC

4 Position Menu Activated Switch

Model 4P-MAS

Summary of Contents for 4P-MAS

Page 1: ...all 4P MAS parameters Lead Control This option allows any of the four ports can access the master port by raising its Request To Send RTS or Data Terminal Ready DTR control lead This capability is in...

Page 2: ...emember your code When connecting through a modem three incorrect attempts to enter the security code will cause the 4P MAS to terminate the call When the correct code is entered the Main Menu appears...

Page 3: ...s This allows changing of the screen labels for the ports A PORT A B PORT B C PORT C D PORT D X EXIT ENTER LABEL A D Enter the label to be changed The current label is displayed along with a prompt fo...

Page 4: ...bits and 1 stop bit Set Lead Control ENTER Y N Enter Y to add RTS DTR Lead control to the 4P MAS This mode allows the RTS or DTR of Ports A through D to select the Master Port Change this setting to Y...

Page 5: ...logged into the unit or Manual control is selected the RTS and DTR leads are ignored The Timeout feature if enabled continues to operate when Lead control selects a port Once a port is selected due t...

Page 6: ...gh JP4 allows selection of RTS or DTR as the control lead used in the Code Lead Control mode To access these jumpers disconnect the power source and remove the top cover of the 4P MAS by loosening the...

Page 7: ...in a separate document With the modem installed the Master Port RS 232 port can still be used With the Modular Adaptor removed an external modem or terminal with null cable can be directly connected t...

Page 8: ...t 201 967 8788 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shipment THIS WARRANTY...

Reviews: