Í
Ribbon Loading
(perform only if
equipped with the
optional
Thermal Transfer
feature)
a) Ensure that the Media Type
Switch is in the Transfer
position:
Media Type Switch
Direct
Transfer
b) Remove and load the Hubs:
Ribbon
Empty Core
Slide a Ribbon onto a Hub and
an Empty Core onto a Hub
Push in and lift
to remove the Hubs
c)
Replace the Hubs so that
the ribbon flows as shown
below:
þ
Note:
Ensure the inked side of
the ribbon faces the
media and NOT the
printhead.
d) Route the ribbon through the printer, as shown below:
Wrap the end of the ribbon
around the Empty Core
and secure it in place
PRINTER SETUP MODE DEFAULT VALUES TABLE*
#
Menu Item
Default
Value
#
Menu Item
Default
Value
1
2
3
4
5
6
7
8
9
10
MEDIA TYPE
SENSOR TYPE
PRESENT SENSOR
CUTTER EQUIPPED
SOP ADJUST
PRESENT ADJUST
BAUD RATE
DATA, PARITY
CONTROL CODES
CONT FORM LENGTH
DIRECT
EDGE
NO
NO
128
128
9600
8, N
STANDARD
100
11
12
13
14
15
16
17
18
19
20
21
OOS MAXVOLT
TOF GAIN
TOF DELTA
TOF LOW
LABEL WIDTH
SCALABLE FONT
INTERNAL MODULE
LABEL ALIGNMENT
ALIGN LENGTH
STOP LOCATION
INPUT MODE
2
10
10
0
410
64
128
NO
100
HOST
DPL
Î
Printer Front
Panel
’
Additional
Information
This table contains a list of the
printer’s menu items and the
associated default values.
These values can be changed
in the Printer Setup Mode.
*
Certain item values can also be controlled via software.
‘
Test Label
Printing
With the printer ‘On’ and loaded with 4 inch wide media (and
ribbon, if needed):
Press the
+
buttons simultaneously; this will print
the Database Configuration Label.
Ÿ
For unpacking/repackaging information see the
Operator’s Manual
.
Ÿ
Follow and perform the suggested maintenance as detailed in the
Operator’s Manual
.
Ÿ
For detailed information on the topics referred to in this guide consult the
Operator’s
Manual
; for detailed information on custom programming see the
E-Class Programmer’s
Manual
included on the Accessories CD-ROM.
Contacting Datamax…
Corporate Headquarters
(407) 578-8007
Technical Support
(407) 523-5540