76
A-Class
Step
Action
Displayed Message
Comment
G
Observe the calibration
result.
CALIBRATION COMPLETE
Calibration was
successful.
;
If ‘Warning Low
Backing’ is displayed,
calibration was
successful (for
possible messages
see Section 5.1).
H
Press the ESC Key
repeatedly to exit menu
mode.
CALIBRATION COMPLETE
Followed by...
READY
When calibrating gap or
reflective media, press
and hold the FEED Key
until at least one label is
output.
The printer is now ready
for use.
5.2.2 Advanced Entry
;
Advanced Entry will override all previous calibration settings and should only be
used when Standard Calibration attempts fail. Ensure that the correct SENSOR
TYPE is selected (see Section 4.2.1) before staring this procedure.
Advanced Entry is an alternate calibration method for special-case media types, where
sensor readings are taken using different sampling algorithms and from a list of these
readings the best algorithm is selected for manual entry into the database. Follow the steps
below to perform an Advanced Entry Calibration:
Step
Action
Displayed Message
Comment
A
Turn ON the printer.
CANNOT CALIBRATE
-or-
UNCALIBRATED
Wait briefly for the printer
to initialize.
(continued)
Summary of Contents for A-Class A-4212
Page 1: ...Operator s Manual ...
Page 2: ......
Page 5: ......
Page 6: ......
Page 8: ......
Page 14: ...vi ...
Page 22: ...8 A Class ...
Page 84: ...70 A Class ...
Page 128: ...114 A Class ...
Page 136: ...122 A Class ...
Page 140: ...126 A Class ...
Page 144: ...130 A Class ...
Page 158: ...144 A Class ...
Page 160: ...146 A Class ...
Page 166: ...152 A Class ...