USE AND FUNCTIONING
3
Default Settings
The following tables contain the default values for the major barcode setup
parameters, according to the type of scan engine mounted on the terminal. For a
complete list of parameters and of their configuration procedures, please refer to the
SDK Help file on the CD.
SCAN PARAMETERS
HP
XLR
Scan Timeout
5000
5000
Beep Duration
20
20
Beep Frequency
2000
2000
LED Duration
0
0
LED Pulses
0
0
Continuous Mode
Disabled
Disabled
Keyboard Emulation
Disabled
Disabled
Soft Trigger
Enabled
Enabled
Scan Always On
Disabled
Disabled
GENERAL READER PARAMETERS
HP
XLR
Barcode Symbology Identifier
None
None
Aim Mode
Timed Hold
Timed Hold
Aim Duration
0
0
SYMBOLOGY SPECIFIC
READER PARAMETERS
HP XLR
UPC A
Enabled Enabled
UPC E
Enabled Enabled
UPC E1
Disabled
EAN 8
Enabled Enabled
EAN 13
Enabled Enabled
EAN Bookland
Disabled
Code 39
Enabled Enabled
Code 39 Full ASCII
Disabled Disabled
Code 32
Disabled Disabled
Code 39 Trioptic
Disabled
2/5: Interleaved
Enabled Enabled
2/5: Industrial
Disabled Disabled
2/5: Matrix
Disabled
Code 128
Enabled Enabled
EAN 128
Enabled Enabled
ISBT 128
Disabled
23