3.2.2 AUX INTERLOCK CONNECTION
Plug Aux interlock connector to marking system.
Figure 20: Connecting Aux interlock connector.
WARNING!
If the Aux interlock gold connector is used, the marking system is in
DANGEROUS
condition
(MUTING DEVICE)
NOTE:
The Aux interlock cable must always be inserted in order to use the marking system. The absence of
such connector locks the marking system.
3.2.3 POWER SUPPLY CABLE CONNECTION
Connect power supply cable to Ulyxe PL™. Check connector right orientation and plug in. Once plugged in
check also right coupling between two connectors parts.
Figure 21: Power Supply cable plug in.
WARNING!
Ulyxe PL™
needs a
safety circuit
for emergency. Consult chapter 2.6 for more details.
WARNING!
Ulyxe PL™
needs a 24V DC stabilized supply voltage 13A max current absorption. It is suggested to
use
BOXED POWER SUPPLY KIT
option. See chapter 5.2.