TECHNICAL SPECIFICATIONS
23
2
2.4.2.1
LASER CONTROL SIGNALS TIMING
Figure 12: Timing control signals.
2.4.2.2
MARKING PROCESS SIGNALS TIMING
The following diagram illustrates the possible timings and settings of these signals:
Figure 13: Timing signals.
The time intervals in the diagram can all be programmed by a resolution of 1 ms.
T
1
Start Time
For setting the minimum acceptable time for the start marking signal
T
2
Start Delay
For delaying marking start
T
3
Busy Advance
BUSY
signal corresponding to mark progress
T
4
Stop Time
The minimum time for
STOP
signal to stop the marking process
T
5
Busy Delay
For delaying the Laser
END
signal with respect to laser emission
T
6
End Time
For setting the Laser
END
activation time