SG-DM INSTRUCTION MANUAL 

 

2  

 

NOTES AND WARNINGS 

 

  To guarantee the correct functioning of the safety light curtains, we recommend the use 

of no more than three deviating mirrors to deviate the beam along the optic path. 

  Each mirror used decreases the operating range of the safety light curtain by 15%, 20%, 

25%. Apply a correction factor of 85% using one mirror, 65% using two mirrors, 50% for 
three mirrors. 

  To maintain the correct functioning of the system, we advise to periodically clean the 

mirror surface using a damp non-abrasive cloth. The cleaning frequency depends on the 
system’s surrounding environment. 

  The mirror length has to be at least 100 mm superior to the length of the light curtain’s 

protected area. 

  The mirror has to be mounted in such a manner that its axis (horizontal and vertical) 

coincide with the corresponding safety device axis. 

  The mirror has to be solidly fixed to avoid accidental movements or strong vibrations. 

  The use of the SE-S floor stand or the SG-PSB Protective Armor Stands is 

recommended. The mirror is fixed to these using the appropriate accessory mounting kit. 
The use of the “SE-DM K DEVIATING MIRROR FIXING KIT” (cod.95ACC2530) is 
recommended when installing the devices in environments characterized by strong 
temperature variations and/or in presence of vibrations. 

  Given the limited mirror width, the entire system is particularly sensitive also to small 

rotations along the vertical axis of the mirror and emitting and receiving units. 

  Hence particular attention has to be taken during system alignment and part fixing. 

  To facilitate system installation (mirror/s and safety light curtain) the use of the Datalogic 

SG-LP laser pointer is suggested. 

 
The drawing shows an area protection system composed of a safety light curtain and two 
mirrors. 
 

 

Figure 1 

Emitter 

Receiver 

Corner Mirror

Corner Mirror

Summary of Contents for SG-DM

Page 1: ...SG DM Deviating Mirrors Instruction Manual Figure A 821001930 Rev 00 ...

Page 2: ...rresponding safety device axis The mirror has to be solidly fixed to avoid accidental movements or strong vibrations The use of the SE S floor stand or the SG PSB Protective Armor Stands is recommended The mirror is fixed to these using the appropriate accessory mounting kit The use of the SE DM K DEVIATING MIRROR FIXING KIT cod 95ACC2530 is recommended when installing the devices in environments ...

Page 3: ... first mirror in a central point of the vertical axis and at the same height at which the pointer is installed 6 Repeat the same procedure inserting the pointer in the lower part of the unit if necessary repeat these procedures until the desired result is achieved 7 Orient the first mirror in order that the laser beam hits the second mirror as described above 8 For the angular adjustment rotate th...

Page 4: ...for installation and adjustment procedures CORRESPONDING MODELS SG DM CORRESPONDING SAFETY LIGHT CURTAIN SGx xx 015 SGx xx 030 SG DM 600 SGx xx 045 SGx xx 060 SGx xx 075 SG DM 900 SG4 40 060 SG2 S2 050 SG4 S2 050 SG2 B2 050 SG4 B2 050 SG4 BLR2 050 2x SG DM 150 SG DM 900 SG4 BSR2 050 SGx xx 090 SGx xx 105 SG DM 1200 SG4 40 090 SG2 S3 080 SG4 S3 080 SG2 B3 080 SG4 B3 080 SG4 BLR3 080 3x SG DM 150 SG...

Page 5: ...ONDING SAFETY LIGHT CURTAIN SG2 S4 120 SG4 S4 120 SG2 B4 120 SG4 B4 120 SG4 BLR4 120 4x SG DM 150 SG DM 1650 SG4 BSR4 120 SGx xx 165 SG DM 1900 SGx xx 180 OVERALL DIMENSIONS Model 150 including ST DM stand alone bracket mounting kit Figure 3 ...

Page 6: ...arge any product found to be defective during the warranty period of 36 months from the manufacturing date This warranty does not cover damage or liability deriving from the improper application of DATALOGIC AUTOMATION products DATALOGIC AUTOMATION Via Lavino 265 40050 Monte S Pietro Bologna Italy Tel 39 051 6765611 Fax 39 051 6759324 www automation datalogic com e mail info automation datalogic c...

Reviews: