Identification Parameters
Index
(dec)
Parameter
Object Name
Lenght
Subindex
(offset)
Value/Range
Description
Data Type Access* Remark
0x0010 (16)
Vendor Name
9 octets
DATALOGIC
Informative
StringT
RO
0x0011 (17)
Vendor Text
19 octets
Empower your vision
StringT
RO
0x0012 (18)
Product Name
15 octets
See “Device variant collection” on page 2
Detailed product name
StringT
RO
0x0013 (19)
Product ID
5 octets
See “Device variant collection” on page 2
Product identification
StringT
RO
0x0014 (20)
Product Text
21 octets
See “Device variant collection” on page 2
StringT
RO
0x0015 (21)
Serial Number
9 octets
Unique serial number
StringT
RO
0x0016 (22)
Hardware
Revision
5 octets
RevAD
StringT
RO
0x0017 (23)
Firmware
Revision
5 octets
4.0.0
StringT
RO
0x0018 (24)
Application
Specific Tag
32 octets
*** (default)
Tag application defined by user
StringT
R/W
Saved in non-volatile memory
0x0019 (25)
Function Tag
32 octets
*** (default)
Additional tag for device function identification
StringT
R/W
Saved in non-volatile memory
0x001A (26)
Location Tag
32 octets
*** (default)
Additional tag for device function identification
StringT
R/W
Saved in non-volatile memory
Observation / Diagnostic Parameters
Index
(dec)
Parameter
Object Name
Lenght
Subindex
(offset)
Value/Range
Description
Data Type Access* Remark
0x0028 (40)
Process Data
Input
3 octets
Read last valid Process Data Input from PDin channel
Device
specific
RO
0x0029 (41)
Process Data
Output
1 octet
Read last valid Process Data Output from PDout channel
Device
specific
RO
0x0052 (82)
Device
Temperature
2 octets
2 octets
2 octets
2 octets
2 octets
1(64)
2(48)
3(32)
4(16)
5(0)
Device temperature actual
Device min. temperature since powerup
Device max. temperature since powerup
Device min. temperature during lifetime
Device max. temperature during lifetime
IntegerT
IntegerT
IntegerT
IntegerT
IntegerT
RO
RO
RO
RO
RO
0x0053 (83)
Device
Temperature
Threshold
2 octets
2 octets
1(16)
2(0)
Device min. temperature threshold (
B01, C01, T01
)
Device max. temperature threshold (
B01, C01, T01
)
IntegerT
IntegerT
R/W
Saved in non-volatile memory
every hour. Events are generated
if the device temperature exceeds
the thresholds.
0x0057 (87)
Operating Hours
4 octets
4 octets
4 octets
1(64)
2(32)
3(0)
0...(2^32)-1
Operating Hours: device operating hours. Not resettable by user.
Operating Hours Maintenance: device operating hours, reset on
system command “Confirm Maintenance”.
Operating Hours Power Up: Time in hours since power up.
UIntegerT
UIntegerT
UIntegerT
RO
RO
RO
0x0024 (36)
Device Status
1 octet
0x00 → Device is operating properly
0x01 → Maintenance Required
0x02 → Out of specification
0x03 → Functional Check
0x04 → Failure
Contains current status of the device
UIntegerT
RO
0x0025 (37)
Detailed Device
Status
3 octets
Information about currently pending Events.
Implemented as dynamic list.
UIntegerT
RO
0x00BE (190) Excess gain
2 octets
100...900
Excess gain (EG) = 0 if signal is under threshold (
B01 LED, C01,
T01
)
UIntegerT
RO