UPC/EAN Global Settings
Product Reference Guide
109
ENTER/EXIT PROGRAMMING MODE
UPC/EAN Global Settings — cont.
UPC/EAN Minimum Segment Length
Specifies the minimum number of characters necessary in an UPC/EAN/JAN label segment in
order for the reader to accept the segment for decoding.
$CUNSL05
UPC/EAN Minimum Segment Length Block = 5
$CUNSL06
UPC/EAN Minimum Segment Length Block = 6
$CUNSL07
UPC/EAN Minimum Segment Length Block = 7
$CUNSL08
UPC/EAN Minimum Segment Length Block = 8
$CUNSL09
UPC/EAN Minimum Segment Length Block = 9
$CUNSL0A
UPC/EAN Minimum Segment Length Block = 10