6
PWR-240B
CHAPTER 4
LOW VOLTAGE ELECTRICAL
CONNECTIONS
DC LOW VOLTAGE CABLE INSERTION
The Cable Entry Plate has several sealing grommets that must be inserted to provide
IP65 protection capability. This includes AS-I cable sealing grommets.
Cable Entry Plate
Follow these instructions to correctly insert the cables:
1. Determine the number and size of the cables coming into and leaving the PWR-
240B.
2. Unmount the Cable Entry Plate and select all the necessary grommets for your
application.
3. Insert the correct size sealing grommets and positions relative to these cables.
Unused positions must mount the closed grommets with their flat closed surface
facing the outside of the PWR.
4. Remount the Cable Entry Plate.
5. Press the cable end through the proper grommet so that it seals around the cable.
The Cable Entry Plate has 10 cable entry points with the following grommet kit supplied:
GROMMETS
CABLE DIAMETER
QTY
TYPE
MM
INCH
2
single
3
0.118
1
double
4
0.157
1
single
6
0.236
4
double
6
0.236
2
AS-I Cable form
-
-
7
closed
-
-