DATA MATRIX
ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
225
Data Matrix Length Control
This feature specifies either variable length decoding or fixed length decoding for this
symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may
be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
Data Matrix Set Length 1
This feature specifies one of the bar code lengths for "
Data Matrix Length Control" on
. Length 1 is the minimum label length if in Variable Length Mode, or the first
fixed length if in Fixed Length Mode. Characters can be set from 0001 to 3,116 charac
-
ters in increments of 0001 (pad with zeroes).
See "
for detailed instructions on setting this feature.
$CDMLC00
Data Matrix Length Control = Variable Length
Data Matrix Length Control = Fixed Length
$CDMLC01
Select Data Matrix Length 1 Setting
$CDML1
To configure this feature, scan the ENTER/EXIT PRO
-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu
-
meric characters in
represent
-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
0001 = Length 1 is 1 Character