SCANNING FEATURES
ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
111
Flash Off Time
This feature specifies the OFF time for the indicator LED while in Flash Mode. The select
-
able range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond incre
-
in “References” for detailed information on setting this feature.
Double Read Timeout
Double Read Timeout prevents a double read of the same label by setting the minimum
time allowed between reads of labels of the same symbology and data. If the unit reads
a label and sees the same label again within the specified timeout, the second read is
ignored. Double Read Timeout does not apply to scan modes that require a trigger pull
for each label read.
Select Flash OFF Time Setting
$CSNFF
To configure this feature, scan the ENTER/EXIT PRO
-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu
-
meric characters in
represent
-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
06 = Flash is OFF for 600ms
$CSNDR0A
Double Read Timeout = 0.1 Second
Double Read Timeout = 0.2 Second
$CSNDR14
$CSNDR28
Double Read Timeout = 0.4 Second