background image

ii

PowerScan™ Retail PM9500-RT

Summary of Contents for PowerScan PD9530-HP

Page 1: ...PowerScan PD9530 Industrial Corded Handheld Area Imager Bar Code Reader Quick Reference Guide...

Page 2: ...u can acquire printed versions by contacting your Datalogic repre sentative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media...

Page 3: ...Tables 8 Keyboard Interface 8 Country Mode 9 Caps Lock State 13 Numlock 14 Programming 15 Using Programming Bar Codes 15 Configure Other Settings 15 Resetting Product Defaults 15 Reading Parameters 1...

Page 4: ...ii PowerScan Retail PM9500 RT...

Page 5: ...r information implementation tech niques and trade secrets related to the Software b any other trade secrets marked appropriately or identified as proprietary or confidential and c any information tha...

Page 6: ...2 End User shall not disclose provide or otherwise make available the Propri etary Information of Datalogic or its third party licensors to any person other than End User s authorized employees or age...

Page 7: ...laws and with the English language version of this Agreement The provisions of the United Nations Convention on International Sale of Goods shall not apply to this Agreement 10 Termination 10 1Either...

Page 8: ...Datalogic shall have the right at its absolute discretion to initiate proceedings in the courts of any other state country or territory in which End User resides or in which any of End User s assets...

Page 9: ...sity codes DPM laser ink jet and dot peen Omni directional Operating To read a symbol or capture an image you simply aim the reader and pull the trigger Since the PowerScan PD9530 is a powerful omni d...

Page 10: ...owerScan PD9530 can also function as a camera by capturing entire images or image portions of labels signatures and other items Autoscanning An autoscan command causes the reader to scan continuously...

Page 11: ...the Front marking on the Cable Holder is facing out with the arrow pointing towards the front of the scanner 4 Insert the end of the cable into the socket of the Cable Holder 5 Push the Cover along th...

Page 12: ...system will be smaller when the reader is closer to the bar code and larger when it is farther from the code Symbologies with smaller bars or elements mil size should be read closer to the unit Symbol...

Page 13: ...provided in this section For defaults and addi tional information associated with each interface proceed to the corresponding chapter in the PowerScan PD9530 PRG Configuring the Interface Scan the ap...

Page 14: ...Interface Type 6 PowerScan PD9530 RS 232 RS 232 standard interface RS 232 RS 232 Wincor Nixdorf RS232 WN RS 232 for use with OPOS UPOS JavaPOS RS 232 OPOS USB USB Com to simulate RS 232 standard inter...

Page 15: ...ued USB OEM can be used for OPOS UPOS JavaPOS USB OEM a Download the correct USB Com driver from www datalogic com USB Keyboard with standard key encoding USB KBD USB Keyboard with alternate key encod...

Page 16: ...haracter emulation for keyboard interfaces Keyboard Interface KEYBOARD WEDGE IBM AT or PS 2 PCs Standard Key Encoding KBD AT IBM AT or PS 2 PCs Standard Key Encoding without external keyboard KBD AT N...

Page 17: ...ted by the keyboard This option is usable only with USB KBD and Keyboard Wedge interface without the Alternate Key mode COUNTRY MODE ENTER EXIT PROGRAMMING MODE Country Mode U S Country Mode Belgium C...

Page 18: ...530 COUNTRY MODE continued Country Mode Czech Country Mode Denmark Country Mode France Country Mode French Canadian Country Mode Germany Country Mode Hungary Supports only the interfaces listed in the...

Page 19: ...Guide 11 COUNTRY MODE continued Country Mode Italy Country Mode Japanese 106 key Country Mode Lithuanian Country Mode Norway Country Mode Poland Country Mode Portugal Supports only the interfaces lis...

Page 20: ...e 12 PowerScan PD9530 COUNTRY MODE continued Country Mode Romania Country Mode Spain Country Mode Sweden Country Mode Slovakia Country Mode Switzerland Supports only the interfaces listed in the Count...

Page 21: ...the format in which the reader sends character data This applies to keyboard wedge interfaces This does not apply when an alternate key encoding key board is selected ENTER EXIT PROGRAMMING MODE Caps...

Page 22: ...on specifies the setting of the Numbers Lock Numlock key while in keyboard wedge interface This only applies to alternate key encoding interfaces It does not apply to USB keyboard ENTER EXIT PROGRAMMI...

Page 23: ...ode once to enter Programming Mode scan the desired parameter settings scan the ENTER EXIT bar code again to accept your changes which exits Program ming Mode and returns the reader to normal operatio...

Page 24: ...si tion time and if no code is decoded will switch on again before the next acquisition The illuminator will remain on until the symbol is decoded As you read code symbols adjust the distance at which...

Page 25: ...ts undesired multiple reads while in this mode Trigger Hold Multiple When the trigger is pulled scan ning starts and the product scans until the trigger is released or maximum scan on time 1 has elaps...

Page 26: ...tion is detected Motionix motion sensing technology Scan the Enter Exit Programming bar code above then either of the barcodes below ENTER EXIT PROGRAMMING MODE Scan Mode Trigger Single Scan Mode Trig...

Page 27: ...or transmitted to the host It is active only while the scanner is in Trigger Single mode If the scanner switches to a different Read Mode Pick Mode is automatically dis abled Multiple Label Reading Th...

Page 28: ...Description Physical Characteristics Dimensions Height 212 mm Length 110 mm Width 74 mm Weight without cable 330 gr without cable Electrical Characteristics Voltage Cur rent PD9530 PD9530 HP PD9530 H...

Page 29: ...tion 2D 7 5 mils 1D 2 5 mil 2D 4 mil Depth of Field Typical a Symbology Standard Model High Performance Code 39 4 mils 6 17 cm 20 mils 4 55 cm 40 mils 4 85 cm 2 5 mils 2 6 cm 20 mils 3 70 cm 40 mils 3...

Page 30: ...Code RM45CC IMB stacked codes including EAN JAN Composites GS1 Databar Com posites GS1 Databar Expanded Stacked GS1 DataBar Stacked GS1 DataBar Stacked Omnidirectional MacroPDF Micro PDF417 PDF417 UPC...

Page 31: ...r beeps four times at highest fre quency and vol ume upon power up Good Read Beep A label has been successfully scanned by the reader LED behavior for this indica tion is configu rable via the feature...

Page 32: ...el the soft ware shall turn the green spot on for the time specified by the configured value N A N A Image Cap ture When ready to capture image Blue light flashes 2 times when updating N A a Except wh...

Page 33: ...abel Pro gramming Mode Accep tance of Par tial Label In cases where multiple labels must be scanned to program one feature this indica tion acknowledges each portion as it is successfully scanned N A...

Page 34: ...d Replaceable Unit isolation mode If the reader is reset the sequence will be repeated Press and release the trigger to hear the FRU indication code The following table describes the LED flashes beep...

Page 35: ...ce during scanning Use a soft dry cloth to clean the product If the product is very soiled clean it with a soft cloth moistened with a diluted non aggressive cleaning solution or diluted ethyl alcohol...

Page 36: ...rom the date of shipment from Datalogic for the duration published by Datalogic for the product at the time of purchase Warranty period Datalogic warrants repaired hardware devices against defects in...

Page 37: ...indow in accordance with product manual v any defect or damage caused by natural or man made disaster such as but not limited to fire water damage floods other natural disasters vandalism or abusive e...

Page 38: ...uct to Customer Datalogic will select the carrier but Datalogic shall not thereby assume any liability in connection with the return shipment Ergonomic Recommendations Reduce or eliminate repetitive m...

Page 39: ...ndustrial Handheld Scanners category link From this page you can select your product model from the drop down list which gives you access to Downloads including Data Sheets Manuals Software Utilities...

Page 40: ...Support Through the Website 32 PowerScan PD9530...

Page 41: ......

Page 42: ...Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U Datalogic USA Inc 959 Terry Street Eugene OR 97402 USA Telephone 541 68...

Reviews: