LED and Beeper Indicators
Product Reference Guide
29
Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains on following
a good read. The good read LED on time can be set within a range of 10 milliseconds to
2,550 milliseconds (0.001 to 2.55 seconds) in 10ms increments.
Follow these instructions to set this feature:
1. Determine the desired setting in milliseconds. A setting of 0 means that the good read
LED stays on until the next time the trigger is pulled.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with lead-
ing zeroes to yield three digits. For example: 0 = 000, 5 = 000, 20 = 020, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
4. Scan the barcode: SELECT GOOD READ LED DURATION SETTING.
5. Scan the appropriate three digits from the keypad in
representing the
duration which was determined in the steps above. You will hear a two-beep indication
after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
for some examples of how to set this feature.
Table 3. Good Read LED Duration Setting Examples
NOTE
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
STEP
ACTION
EXAMPLES
1
Desired Setting
Good Read LED
stays on until next
trigger pull (00)
20ms
150ms
2550ms (2.55 sec.)
2
Divide by 10 (and pad with leading
zeroes)
000
002
015
255
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT LABEL GONE TIMEOUT SETTING
5
Scan Three Characters From
‘0’, ‘0’ and ‘0’
‘0’, ‘0’ and ‘2’
‘0’, ‘1’ and ‘5’
‘2’, ‘5’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for POWERSCAN PBT7100 guide
Page 1: ...PowerScan PBT7100 Cordless Linear Imaging Barcode Reader Product Reference Guide...
Page 10: ...8 PowerScan PD7100 Corded NOTES...
Page 14: ...Introduction 4 PowerScan PBT7100 Cordless NOTES...
Page 56: ...General Features 46 PowerScan PBT7100 Cordless NOTES...
Page 82: ...RS 232 USB Com Interfaces 72 PowerScan PBT7100 Cordless NOTES...
Page 104: ...IBM 46XX Interface 94 PowerScan PBT7100 Cordless NOTES...
Page 281: ...Follett 2 of 5 Product Reference Guide 271 NOTES...
Page 282: ...Symbologies 272 PowerScan PBT7100 Cordless...
Page 328: ...318 PowerScan PBT7100 Cordless NOTES...
Page 332: ...322 PowerScan PBT7100 Cordless NOTES...
Page 334: ...324 PowerScan PBT7100 Cordless 6 7 8 9 A B C...
Page 335: ...Product Reference Guide 325 D E F...
Page 336: ...326 PowerScan PBT7100 Cordless NOTES...
Page 346: ...Product Reference Guide 336 IBM XT Table F 9 Scancode Set When Control Character is 00 or 01...
Page 347: ...Product Reference Guide 337 IBM XT cont Table F 10 Scancode Set When Control Character is 02...