Messages from Host to Reader
Product Reference Guide
177
Font Selection
ESC [ 0 m
Normal mode
ESC [ 7 m
Reverse mode
ESC # 4
Large font: subsequent characters are written on the current row and the
row below it using the 12x16 font which allows for two rows of eight char-
acters on the display.
ESC # 5
Normal font: subsequent characters are written using the 6x8 font, which
allows for four rows of sixteen characters on the display.
ESC # 7
Medium font: subsequent characters are written using the 8x8 font, which
allows for four rows of twelve characters on the display.
Clearing Display
LED and Beeper Control
The LED control escape sequences are intended to activate the LEDs for short periods of
time and can be used in combination with the Beeper. The LED and Beeper will be
controlled by the system after the entire command sequence is interpreted.
Example:
Setting RTC
ESC [ 0 K
From cursor position to end of line inclusive
ESC [ 1 K
From beginning of line to cursor position (not inclusive)
ESC [ 2 K
Entire line
ESC [ 0 J
From cursor position to end of display inclusive
ESC [ 1 J
From beginning of display to cursor position (not inclusive)
ESC [ 2 J
Entire display; moves cursor to upper left corner on display
ESC [ 0 q
Emit short High tone + short delay
ESC [ 1 q
Emit short Low tone + short delay
ESC [ 2 q
Emit long Low tone + short delay
ESC [ 3 q
Emit good read tone
ESC [ 4 q
Emit bad tx tone
ESC [ 5 q
Wait 100 ms
ESC [ 6 q
Turn on the green LED
ESC [ 7 q
Turn off the green LED
ESC [ 8 q
Turn on the red LED
ESC [ 9 q
Turn off the red LED
ESC [ 6 q ESC [ 3 q ESC [ 7 q
Turns on the green LED, emits a good read tone, and turns
off the green LED.
ESC [ 6 q ESC [ 5 q ESC [ 7 q
Turns on the green LED for 100 ms and then turns off the
green LED.
ESC [ 0 p
d d m m y y
Set date to day, month, year
ESC [ 1 p
h h m m
Set time to hours, minutes; seconds are automatically set
to 00.
Summary of Contents for PowerScan M8500
Page 17: ...Preface 14 PowerScan M8500 NOTES...
Page 28: ...Installation Product Reference Guide 25 WEDGE Connection PEN Emulation Connection...
Page 55: ...PowerScan M8500 Setup 52 PowerScan M8500 NOTES...
Page 137: ...Configuration Using Code Symbols 134 PowerScan M8500 NOTES...
Page 157: ...Advanced Data Formatting 154 PowerScan M8500 NOTES...
Page 211: ...Host Configuration Strings 208 PowerScan M8500 NOTES...
Page 219: ...Sample Barcodes 216 PowerScan M8500 QR PDF417 DataMatrix Normal DataMatrix Inverse PDF417...
Page 225: ...Hex Numeric Table 222 PowerScan M8500 AUTOSCAN PATTERN CODE s...
Page 226: ...Product Reference Guide 223 NOTES...
Page 227: ...Hex Numeric Table 224 PowerScan M8500 NOTES...
Page 232: ......